Quality IPX4 Black Air Source Heat Pump with 6L Expansion Tank Monobloc Heat Pump factory
Quality IPX4 Black Air Source Heat Pump with 6L Expansion Tank Monobloc Heat Pump factory

IPX4 Black Air Source Heat Pump with 6L Expansion Tank Monobloc Heat Pump

IPX4 Black Air Source Heat Pump with 6L Expansion Tank Monobloc Heat Pump
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
PW08-DKXLRE1-H8
Trading Properties
MOQ
3 pcs
Unit Price
$2500-5000
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

IPX4 black R290 monobloc air source heat pump with 6L expansion tank and full DC inverter, delivering heating, cooling and hot water from one compact outdoor unit.

Product Details
Highlight:

Residential Air Source Heat Pumps IPX4

,

Cold Climate Residential Air Source Heat Pumps

,

Full DC Inverter Air Source Heat Pump

Expansion Tank: 6L
Refrigerant: R290
IP Grade: IPX4
Color: Black
Noise: ≤35dB
Heating Capacity: 6kw-16kw
Type: Air Source Heat Pump
Series: H8 Helios Pro Series
Product Description
Product Overview

The H8 Helios Pro Series is an advanced R290 air source heat pump engineered to deliver efficient heating, cooling, and domestic hot water from a single compact monobloc system.

Powered by Full DC Inverter technology, the H8 automatically adjusts its operating capacity to match actual heating demand. Combined with natural R290 refrigerant, high-temperature water output, and intelligent control, it offers an efficient and flexible solution for modern residential and commercial heating systems.

With operation down to -25 °C and water outlet temperatures up to 75 °C, the H8 is built for demanding climates and a wide range of heating applications.

Main Features
Full DC Inverter for Efficient Operation

The variable-speed compressor and fan continuously adjust system output according to the required heating or cooling load. This reduces unnecessary energy consumption while maintaining stable water temperatures and comfortable indoor conditions.

R290 Natural Refrigerant

The H8 uses R290 refrigerant with GWP=3, supporting the transition toward more environmentally friendly heating technologies. A two-stage refrigerant leakage protection system provides additional safety during operation.

Up to 75 °C High-Temperature Water

The H8 can produce outlet water temperatures of up to 75 °C, expanding its compatibility with a wide range of heating applications.

Reliable Performance in Cold Climates

With a working temperature down to -25 °C, the H8 is designed for cold-weather heating applications. Its AI intelligent defrost system automatically manages defrost cycles to help maintain stable heating performance and minimize unnecessary interruptions.

A+++ Energy Efficiency

The H8 achieves ErP A+++ efficiency at both 35 °C and 55 °C, making it suitable for both low-temperature and higher-temperature heating systems.

Quiet Heating for Residential Applications

Advanced fan and compressor noise reduction technology keeps operating sound as low as 35 dB(A) at 1 meter, making the system suitable for homes, villas, and other environments where low operating noise is important.

Intelligent Heating Management

The H8 combines local controls with connected smart management functions. The 7-inch touchscreen controller provides an intuitive interface for daily operation and system configuration. The temperature curve function helps the system adapt its operation to changing heating requirements and outdoor conditions.

Scalable Cascade Heating

For projects requiring higher heating capacity, up to 8 H8 units can operate in cascade. This allows the system to be expanded according to project requirements without relying on a single oversized unit.

Smart Grid Compatible

The H8 Helios Pro Series supports § 14a EnWG-compliant operation, making it suitable for applicable German smart-grid applications. Its smart control architecture allows the heat pump to work with modern energy management strategies and helps optimize electricity usage.

Designed for Modern Heating Systems

The H8 combines several functions in one system: Heating + Cooling + DHW. This makes it a flexible alternative to traditional heating equipment while reducing the need for multiple independent systems. Its monobloc configuration also simplifies system integration by keeping the refrigeration circuit within the outdoor unit.

Suitable Applications
  1. Large residential properties
  2. Villas
  3. Apartment buildings
  4. Small commercial buildings
  5. Heating renovation projects
  6. Multi-zone heating systems
Product Gallery
H8 Helios Pro Series R290 monobloc air source heat pump outdoor unit, front view H8 Helios Pro Series heat pump side view showing hydraulic connections and cabinet design H8 Helios Pro Series heat pump with 7-inch touchscreen controller and system detail view
Technical Specifications
Model Series: PW06 | PW08 | PW10 | PW12 | PW14 | PW16
Parameter / Feature PW06 PW08 PW10 PW12 PW14 PW16
Heating Condition — Ambient Temp. (DB/WB): 7/6 °C, Water Temp. (In/Out): 30/35 °C
Nominal Capacity (kW) 6.08.010.012.014.016.0
Nominal Power Input (kW) 1.191.642.032.392.923.26
COP 5.044.894.925.034.804.90
Heating Condition — Ambient Temp. (DB/WB): 7/6 °C, Water Temp. (In/Out): 47/55 °C
Nominal Capacity (kW) 6.08.010.012.014.016.0
Nominal Power Input (kW) 1.932.633.123.584.355.06
COP 3.113.043.213.353.223.16
Cooling Condition — Ambient Temp. (DB/WB): 35/24 °C, Water Temp. (In/Out): 23/18 °C
Nominal Capacity (kW) 6.08.010.012.014.016.0
Nominal Power Input (kW) 1.181.581.942.322.783.37
EER 5.085.065.155.185.034.75
Operating Ranges & Capacity Ratings
Heating Capacity Range (kW) 3.4~8.54.1~11.04.2~12.96.3~17.06.6~19.37.8~22.0
Heating Power Input Range (kW) 0.66~1.920.78~2.560.82~2.911.23~4.121.31~4.791.55~5.47
COP Range 4.43~5.264.30~5.264.43~5.124.13~5.124.03~5.044.02~5.03
DHW Condition — Ambient Temp. (DB/WB): 20/15 °C, Water Temp. (In/Out): 15/55 °C
Heating Capacity Range (kW) 4.6~9.55.8~12.06.0~13.37.7~18.08.0~19.59.3~23.0
Heating Power Input Range (kW) 0.88~2.071.13~2.791.15~2.781.88~3.981.56~4.531.82~5.35
COP Range 4.59~5.234.30~5.134.78~5.214.38~5.324.30~5.134.30~5.11
Heated Water Output (L/H) 205258285365419494
Cooling Condition — Ambient Temp. (DB/WB): 35/24 °C, Water Temp. (In/Out): 12/7 °C
Cooling Capacity Range (kW) 2.2~6.03.3~8.03.4~10.55.0~13.25.6~15.26.4~16.5
Cooling Power Input Range (kW) 0.62~1.930.88~2.590.9~3.251.49~4.521.42~4.811.93~5.79
EER Range 3.11~3.553.09~3.753.23~3.782.92~3.353.16~3.942.85~3.31
Cooling Condition — Ambient Temp. (DB/WB): 35/24 °C, Water Temp. (In/Out): 23/18 °C (Range)
Cooling Capacity Range (kW) 3.3~8.04.5~10.85.1~13.07.9~17.08.2~18.59.5~20.5
Cooling Power Input Range (kW) 0.59~1.880.80~2.510.84~2.781.40~3.721.42~4.201.76~5.06
EER Range 4.26~5.604.30~5.634.68~6.074.56~5.624.40~5.774.05~5.40
Energy Efficiency Ratings (ErP)
ErP Level (55 °C) A+++A+++A+++A+++A+++A+++
ErP Level (35 °C) A+++A+++A+++A+++A+++A+++
Electrical & Hydraulic Specifications
Power Supply 220-240V~, 50/60Hz220-240V~, 50/60Hz220-240V~, 50/60Hz220-240V~, 50/60Hz220-240V~, 50/60Hz220-240V~, 50/60Hz
Max. Power Input (kW) 3.2+3.04.2+3.05.0+3.05.8+3.06.7+3.08.3+3.0
Max. Current (A) 14.6+13.819.2+13.821.7+13.825.2+13.830.7+13.838.0+13.8
Water Flow (m³/h) 1.461.892.222.923.523.78
Water Pressure Drop (max) kPa 303540435860
Diameter of Pipe (mm) DN25DN25DN25DN25DN32DN32
Physical & Operating Specifications
Net Weight (kg) 128165170178182190
Body Size (W×D×H) (mm) 1200×465×7911328×485×10651328×485×10651328×485×10651328×485×10651328×485×1065
IP Grade (Level of Protection) IPX4IPX4IPX4IPX4IPX4IPX4
Refrigerant R290R290R290R290R290R290
Expansion Tank (L) 6L6L6L6L6L6L
Electric Heater 3kW3kW3kW3kW3kW3kW
Operating Ambient Temp. (°C) -25~43 °C-25~43 °C-25~43 °C-25~43 °C-25~43 °C-25~43 °C
Operating Water Temp. (°C) 25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)
25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)
25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)
25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)
25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)
25~70 °C (DHW)
25~75 °C (Heating)
5~25 °C (Cooling)

Note: The data above is for reference only. Please refer to the nameplate on the unit for more specific data.