R32 Refrigerant Residential Air Source Heat Pumps Inverter Pool Heating Pump
R32 Energy Saving Inverter Pool Heat PumpThe R32 Energy Saving Inverter Pool Heat Pump is designed for modern residential swimming pools, combining variable-speed heating technology with solar energy compatibility for more efficient daily operation.Powered by DC Inverter technology, the heat pump ...
R32 Residential Air Source Heat Pumps
,1Ph Residential Air Source Heat Pumps
,Inverter Pool Heating Pump
R32 Energy Saving Inverter Pool Heat Pump
The R32 Energy Saving Inverter Pool Heat Pump is designed for modern residential swimming pools, combining variable-speed heating technology with solar energy compatibility for more efficient daily operation.
Powered by DC Inverter technology, the heat pump automatically adjusts its output according to pool heating demand. This helps reduce unnecessary power consumption while maintaining a more stable water temperature.
Efficient Inverter Pool Heating
Unlike conventional ON/OFF pool heaters, the inverter system can continuously regulate compressor speed based on the required heating capacity.
This provides:
- Reduced energy consumption
- More stable water temperature
- Smooth heating performance
- Lower operating costs
- Efficient part-load operation
The variable-speed design is especially suitable for residential pools where heating demand changes throughout the day and across different seasons.
PV Direct Drive for Solar-Powered Heating
The PV Direct Drive function allows the pool heat pump to work with solar power systems, helping make better use of available renewable energy.
By utilizing solar electricity for pool heating, homeowners can reduce reliance on grid power and improve the overall energy efficiency of their pool system.
Quiet Operation at 40 dB(A)
With an operating noise level as low as 40 dB(A), the heat pump is designed for comfortable residential environments.
Its quiet operation makes it suitable for installation near swimming pools, gardens, villas, and other leisure areas without creating excessive background noise.
R32 Refrigerant
The system uses R32 refrigerant, which combines effective heat-transfer performance with a lower global warming potential than many traditional refrigerants.
It provides a practical refrigerant solution for modern energy-efficient pool heating equipment.
Durable ABS Housing
The unit features a premium ABS housing designed to withstand outdoor pool environments.
The corrosion-resistant enclosure provides additional protection against moisture and everyday exposure while maintaining a clean, modern appearance.
Ideal for Residential Swimming Pools
This inverter pool heat pump is suitable for:
- Residential swimming pools
- Villa pools
- Private leisure pools
- Garden pools
- New pool heating installations
- Pool heating upgrades
Its combination of inverter control, solar compatibility, quiet operation, and durable construction makes it a versatile choice for modern residential pool heating.
| Model / Specifications | PW010-KZXYC-H | PW015-KZXYC-H | PW020-KZXYC-H | PW030-KZXYC-H | PW040-KZXYC-H | PW050-KZXYC-H | PW060-KZXYC-H | |
|---|---|---|---|---|---|---|---|---|
| Advised pool volume | m³ ① | 15~30 | 20~40 | 25~50 | 30~60 | 40~75 | 55~100 | 55~100 |
| Operating air temperature | °C | -7~43°C | ||||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | ||||||||
| Heating capacity | kW | 7.50~1.92 | 9.50~2.10 | 11.00~2.50 | 14.00~3.15 | 17.00~3.75 | 20.00~4.00 | 24.00~4.80 |
| Heating capacity | Btu | 25500~6528 | 32300~7140 | 37400~8500 | 47600~10710 | 57800~13090 | 68000~13600 | 81600~16320 |
| Consumed power | kW | 1.15~0.13 | 1.46~0.14 | 1.83~0.17 | 2.15~0.21 | 2.62~0.25 | 3.33~0.27 | 4.00~0.32 |
| COP | 6.5~14.8 | 6.5~15.0 | 6.0~14.7 | 6.5~15.0 | 6.5~15.0 | 6.0~14.8 | 6.0~15.0 | |
| COP at 50% capacity | 10.5 | 11 | 11 | 10.5 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | ||||||||
| Heating capacity | kW | 5.80~1.42 | 7.2~1.50 | 8.5~1.65 | 10.7~2.40 | 13.0~2.65 | 15.6~2.85 | 18.7~3.42 |
| Heating capacity | Btu | 19720~4828 | 24480~5100 | 28900~5610 | 36380~8160 | 44200~9010 | 53040~9690 | 63580~11630 |
| Consumed power | kW | 1.15~0.20 | 1.43~0.21 | 1.77~0.23 | 2.12~0.34 | 2.58~0.36 | 3.25~0.40 | 3.89~0.49 |
| COP | 5.0~7.1 | 5.0~7.2 | 4.8~7.2 | 5.0~7.1 | 5.0~7.4 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | ||||||||
| Cooling capacity | kW | 4 | 5.2 | 6 | 7.2 | 8.6 | 10.1 | 11.8 |
| General Specifications | ||||||||
| Sound pressure at 1m | dB(A) | 38~48 | 38~48 | 40~50 | 42~51 | 43~52 | 43~53 | 44~54 |
| Sound pressure of 50% capacity at 1m | dB(A) | 40 | 40 | 41 | 43 | 44 | 44 | 45 |
| Sound pressure at 10m | dB(A) | 18~25 | 18~25 | 19~26 | 22~27 | 23~30 | 24~31 | 25~32 |
| Heat exchanger | Spiral titanium tube in PVC shell | |||||||
| Casing | ABS plastic casing black color | |||||||
| Refrigerant | R32 | |||||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | |||||||
| Water connection | mm | Φ50 | ||||||
| Rated input current at air 15°C | A | 5.1~0.9 | 6.3~0.9 | 7.8~1.0 | 9.3~1.5 | 11.3~1.6 | 14.3~1.8 | 17.8~2.3 |
| Advised water flux | m³/h | 2~4 | 2~4 | 3~5 | 4~6 | 6~9 | 8~10 | 9~12 |
| Water pressure drop (max) | kPa | 5 | 5 | 8 | 10 | 12 | 15 | 15 |
| Net weight / Gross weight | kg | 56/68 | 56/68 | 58/70 | 64/76 | 72/86 | 72/86 | 80/94 |
| Product size | mm | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1125X416X765 | 1125X416X765 | 1125X416X765 |
| Operating water temperature | Heating °C | 9~40°C | ||||||
| Operating water temperature | Cooling °C | 9~35°C | ||||||
① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover.
Note: The data above is for reference only, please refer to the nameplate on the unit if for more specific data.