Quality Energy-Efficient R32 Quiet Pool Heating Equipment Suits Villa Hotels factory
Quality Energy-Efficient R32 Quiet Pool Heating Equipment Suits Villa Hotels factory
Quality Energy-Efficient R32 Quiet Pool Heating Equipment Suits Villa Hotels factory

Energy-Efficient R32 Quiet Pool Heating Equipment Suits Villa Hotels

Energy-Efficient R32 Quiet Pool Heating Equipment Suits Villa Hotels
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
PW010-030-KZXYC-B
Trading Properties
MOQ
3 pcs
Unit Price
$825-2003
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

R32 Full DC Inverter pool heater with titanium heat exchanger and metal casing. Up to COP 15.0, 75% energy savings, quiet <54 dB operation. Ideal for villas and hotels, 15-60m³ pools. Corrosion-resistant, eco-friendly, WiFi-ready.

Product Details
Highlight:

Energy Efficient Pool Heat Pump

,

Villa Hotel Quiet Pool Heat Pump

,

R32 Quiet Pool Heat Pump Units

Refrigerant: R32
Applicable Pool Volume: 15m³ – 60m³
Technology Type: Full DC Inverter
Max COP Performance: Up To 15.0
Casing: Metal
Power Supply: 220V~240V/1 Ph/50Hz~60Hz
Product Description
R32 Quiet Energy-Efficient Pool Heating Equipment for Villas and Hotels

Most traditional pool heaters degrade quickly due to chemical corrosion and incur soaring electricity costs during continuous operation. The R32 Eco-Shield Series is built to solve these long-term pain points, delivering superior seasonal thermal performance with minimal maintenance overhead.

Three Core Architectural Advantages
1. Advanced Hydro-Shield Corrosion Resistance

Pool water treatment requires harsh chemicals like chlorine and salt, which quickly deteriorate conventional copper or aluminum heat exchangers. Built with a high-grade titanium heat exchanger integrated into a UV-stabilized ABS composite casing, this system offers complete immunity against chemical erosion and outdoor weathering.

2. High-Efficiency Thermal Intelligence (Up to 75% Energy Reduction)

By absorbing ambient heat energy from the surrounding air rather than generating heat solely through electrical elements, the Eco-Shield series converts 1 unit of electricity into up to 12.9 units of thermal energy. This high COP ratio slashes operating costs by up to 75% compared to standard electric tankless pool heaters.

3. Integrated Dual-Stage Heating & Cooling Protection

Whether you need to raise water temperatures during chilly spring mornings or cool down overheat pools during summer hot spells, the intelligent climate engine maintains constant pool water temperatures across changing weather conditions with minimal vibration and noise (<54 dB).

B2B Commercial Benefits
  • Lower After-Sales Service Costs: Heavy-duty titanium exchangers and corrosion-resistant ABS bodies significantly minimize operational defects and warranty requests.

  • Plug-and-Play Compatibility: Designed to integrate effortlessly into standard 220V pool plumbing and filtration networks.

  • Stronger Market Appeal: Eco-friendly R32 compliance and smart WiFi controls provide strong selling points for green-energy HVAC installers and pool equipment wholesalers.

Model PW010-KZXYC-B PW015-KZXYC-B PW020-KZXYC-B PW030-KZXYC-B PW040-KZXYC-B PW050-KZXYC-B PW060-KZXYC-B PW070-KZXYC-B PW080-KZXYC-B
Advised pool volume (m³) 15~30 20~40 25~50 30~60 40~75 55~100 55~100 60~120 70~130
Operating air temperature (°C) -7~43°C
Performance Condition: Air 27°C, Water 26°C, Humidity 80%
Heating capacity (kW) 7.50~1.92 9.50~2.10 11.00~2.50 14.00~3.15 17.00~3.75 20.00~4.00 24.00~4.80 28.0~5.6 32.5~6.5
Heating capacity (Btu) 25500~6528 32300~7140 37400~8500 47600~10710 57800~13090 68000~13600 81600~16320 95500~19100 110900~22100
Consumed power (kW) 1.15~0.13 1.46~0.14 1.83~0.17 2.15~0.21 2.62~0.25 3.33~0.27 4.00~0.32 4.75~0.37 5.42~0.43
COP 6.5~14.8 6.5~15.0 6.0~14.7 6.5~15.0 6.5~15.0 6.0~14.8 6.0~15.0 6.0~15.0 6.0~15.0
COP at 50% capacity 10.5 11 11 10.5 11 11 11 11 11
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW) 5.80~1.42 7.2~1.50 8.5~1.65 10.7~2.40 13.0~2.65 15.6~2.85 18.7~3.42 21.8~4.36 25.4~5.07
Heating capacity (Btu) 19720~4828 24480~5100 28900~5610 36380~8160 44200~9010 53040~9690 63580~11630 74380~14880 86665~17300
Consumed power (kW) 1.15~0.20 1.43~0.21 1.77~0.23 2.12~0.34 2.58~0.36 3.25~0.40 3.89~0.49 4.54~0.62 5.29~0.72
COP 5.0~7.1 5.0~7.2 4.8~7.2 5.0~7.1 5.0~7.4 4.8~7.0 4.8~7.0 4.8~7.0 4.8~7.0
COP at 50% capacity 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
Cooling capacity (kW) 4 5.2 6 7.2 8.6 10.1 11.8 13.8 15.6
Sound pressure at 1m dB(A) 38~48 38~48 40~50 42~51 43~52 43~53 44~54 45~56 45~57
Sound pressure of 50% capacity at 1m dB(A) 40 40 41 43 44 44 45 48 49
Sound pressure at 10m dB(A) 18~25 18~25 19~26 22~27 23~30 24~31 25~32 26~34 26~35
Heat exchanger Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell Spiral titanium tube in PVC shell
Casing Metal Casing
Refrigerant R32
Power supply 220V~240V/1 Ph/50Hz~60Hz
Water connection (mm) Φ50
Rated input current at Air 15°C (A) 5.1~0.9 6.3~0.9 7.8~1.0 9.3~1.5 11.3~1.6 14.3~1.8 17.8~2.3 20.8~2.8 24.2~3.3
Advised water flux (m³/h) 2~4 2~4 3~5 4~6 6~9 8~10 9~12 10~14 12~16
Water pressure drop (max) kPa 5 5 8 10 12 15 15 20 25
Net weight / Gross weight (kg) 62/75 62/75 64/77 70/83 81/95 81/95 93/108 110/128 115/133
Product size (mm) 980X402X636 1107X503X760 1187X503X900
Operating water temperature(°C) Heating 9~40°C
Operating water temperature(°C) Cooling 9~35°C
① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover.
Note: The data above is for reference only, please refer to the nameplate on the unit if for more specific data.