Large Residential Swimming Pool Heat Pump R32 DC Inverter Heat Pump System
R32 DC Inverter Pool Heat Pump The R32 DC Inverter Pool Heat Pump is developed for medium and large residential swimming pools, with models suitable for pool volumes of approximately 60–130m³. It combines variable-speed inverter technology with heating and cooling functions to provide flexible pool ...
Swimming Pool Inverter Heat Pump System
,Large Swimming Pool Heat Pump
,R32 Inverter Heat Pump System
R32 DC Inverter Pool Heat Pump
The R32 DC Inverter Pool Heat Pump is developed for medium and large residential swimming pools, with models suitable for pool volumes of approximately 60–130m³. It combines variable-speed inverter technology with heating and cooling functions to provide flexible pool temperature management throughout the year.
With a spiral titanium tube heat exchanger, R32 refrigerant and a durable ABS outdoor enclosure, the system is designed for villa pools, private swimming pools and residential leisure applications.
High-Efficiency Heating for Larger Pools
For larger residential pools, heating performance and operating efficiency are equally important. The DC Inverter system adjusts compressor output according to the actual heating requirement, helping the unit adapt to different pool and outdoor conditions.
At 27°C ambient air / 26°C pool water, the heat pump can achieve a COP of up to 15.0, with COP reaching 11.0 at 50% capacity.
Under cooler conditions of 15°C ambient air / 26°C pool water, the tested COP is 4.8–7.0, providing dependable heating performance when outdoor temperatures fall.
Heating and Cooling for Year-Round Use
Rather than providing heating only, this heat pump supports both heating and cooling, allowing pool water temperature to be adjusted across different seasons.
The applicable water temperature ranges are:
Heating: 9–40°C
Cooling: 9–35°C
This makes the unit suitable for residential pools that require temperature management throughout the swimming season.
Titanium Heat Exchange for Pool Water
The heat exchanger uses a spiral titanium tube inside a PVC shell. Titanium is well suited to swimming pool applications, providing a reliable heat-transfer solution for pool water systems.
The heat exchanger design works together with the inverter compressor to deliver stable thermal performance during continuous pool heating and cooling operation.
Designed for Changing Outdoor Conditions
The system operates across an ambient temperature range of -7°C to 43°C, allowing it to handle a broad range of outdoor conditions.
The DC Inverter compressor can vary its output as the heating requirement changes, helping avoid unnecessary full-load operation when the pool only requires partial heating capacity.
Lower Noise at Part Load
Sound pressure is approximately 44–57 dB(A) at 1m, depending on the model. At 50% capacity, operating noise is approximately 45–49 dB(A).
By reducing compressor output when full capacity is not required, the inverter system can provide a quieter operating environment during normal pool temperature maintenance.
Outdoor Housing for Poolside Installation
The heat pump is enclosed in a black ABS plastic casing designed for outdoor use. Its lightweight and corrosion-resistant construction makes it suitable for poolside installations, villa gardens and residential leisure areas.
Applications
The R32 DC Inverter Pool Heat Pump is suitable for:
-
Large residential swimming pools
-
Villa swimming pools
-
Private leisure pools
-
Outdoor swimming pools
-
Residential pool heating and cooling projects
With flexible pool capacity, high-efficiency inverter operation and year-round heating and cooling, this R32 pool heat pump provides a complete temperature control solution for larger residential swimming pools.
| Model / Specifications | PW010-KZXYC-H | PW015-KZXYC-H | PW020-KZXYC-H | PW030-KZXYC-H | PW040-KZXYC-H | PW050-KZXYC-H | PW060-KZXYC-H | |
|---|---|---|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 15~30 | 20~40 | 25~50 | 30~60 | 40~75 | 55~100 | 55~100 |
| Operating air temperature (°C) | -7~43°C | |||||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | ||||||||
| Heating capacity (kW) | 7.50~1.92 | 9.50~2.10 | 11.00~2.50 | 14.00~3.15 | 17.00~3.75 | 20.00~4.00 | 24.00~4.80 | |
| Heating capacity (Btu) | 25500~6528 | 32300~7140 | 37400~8500 | 47600~10710 | 57800~13090 | 68000~13600 | 81600~16320 | |
| Consumed power (kW) | 1.15~0.13 | 1.46~0.14 | 1.83~0.17 | 2.15~0.21 | 2.62~0.25 | 3.33~0.27 | 4.00~0.32 | |
| COP | 6.5~14.8 | 6.5~15.0 | 6.0~14.7 | 6.5~15.0 | 6.5~15.0 | 6.0~14.8 | 6.0~15.0 | |
| COP at 50% capacity | 10.5 | 11 | 11 | 10.5 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | ||||||||
| Heating capacity (kW) | 5.80~1.42 | 7.2~1.50 | 8.5~1.65 | 10.7~2.40 | 13.0~2.65 | 15.6~2.85 | 18.7~3.42 | |
| Heating capacity (Btu) | 19720~4828 | 24480~5100 | 28900~5610 | 36380~8160 | 44200~9010 | 53040~9690 | 63580~11630 | |
| Consumed power (kW) | 1.15~0.20 | 1.43~0.21 | 1.77~0.23 | 2.12~0.34 | 2.58~0.36 | 3.25~0.40 | 3.89~0.49 | |
| COP | 5.0~7.1 | 5.0~7.2 | 4.8~7.2 | 5.0~7.1 | 5.0~7.4 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | ||||||||
| Cooling capacity (kW) | 4 | 5.2 | 6 | 7.2 | 8.6 | 10.1 | 11.8 | |
| General Specifications | ||||||||
| Sound pressure at 1m | dB(A) | 38~48 | 38~48 | 40~50 | 42~51 | 43~52 | 43~53 | 44~54 |
| Sound pressure of 50% capacity at 1m | dB(A) | 40 | 40 | 41 | 43 | 44 | 44 | 45 |
| Sound pressure at 10m | dB(A) | 18~25 | 18~25 | 19~26 | 22~27 | 23~30 | 24~31 | 25~32 |
| Heat exchanger | Spiral titanium tube in PVC shell | |||||||
| Casing | ABS plastic casing black color | |||||||
| Refrigerant | R32 | |||||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | |||||||
| Water connection (mm) | Φ50 | |||||||
| Rated input current at air 15°C (A) | 5.1~0.9 | 6.3~0.9 | 7.8~1.0 | 9.3~1.5 | 11.3~1.6 | 14.3~1.8 | 17.8~2.3 | |
| Advised water flux (m³/h) | 2~4 | 2~4 | 3~5 | 4~6 | 6~9 | 8~10 | 9~12 | |
| Water pressure drop (max) | kPa | 5 | 5 | 8 | 10 | 12 | 15 | 15 |
| Net weight / Gross weight (kg) | 56/68 | 56/68 | 58/70 | 64/76 | 72/86 | 72/86 | 80/94 | |
| Product size (mm) | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1125X416X765 | 1125X416X765 | 1125X416X765 | |
| Operating water temperature (°C) | Heating | 9~40°C | ||||||
| Operating water temperature (°C) | Cooling | 9~35°C | ||||||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. |
||||||||