R32 DC Inverter Silent Pool Heat Pump Quiet Pro Pool Heater
R32 DC Inverter Pool Heat Pump for Residential Swimming Pools The R32 DC Inverter Pool Heat Pump is designed for medium and large residential swimming pools, with model options covering approximately 60–130m³ of pool water. Combining DC Inverter technology, R32 refrigerant, titanium heat exchange, ...
R32 Silent Pool Heat Pump
,DC Inverter Silent Pool Heat Pump
,Silent Pool Heat Pump 380V
R32 DC Inverter Pool Heat Pump for Residential Swimming Pools
The R32 DC Inverter Pool Heat Pump is designed for medium and large residential swimming pools, with model options covering approximately 60–130m³ of pool water.
Combining DC Inverter technology, R32 refrigerant, titanium heat exchange, and heating and cooling functions, the system provides flexible temperature control for villa pools, private swimming pools, and residential leisure projects.
Efficient Inverter Pool Heating
The DC Inverter compressor adjusts its operating capacity according to the actual heating demand, allowing the system to operate efficiently under different load conditions.
Under the rated test condition of 27°C ambient air and 26°C pool water, the system achieves a COP of up to 15.0, while COP at 50% capacity reaches 11.0.
At a lower ambient temperature of 15°C, the tested COP range is 4.8–7.0, providing reliable heating performance in cooler conditions.
Wide Pool Capacity Range
Different models are available for various residential pool sizes:
-
60–120m³
-
70–130m³
-
60–110m³
-
70–130m³
This range allows installers and distributors to select a suitable model according to pool volume and project requirements.
Heating & Cooling in One System
The heat pump supports both pool heating and cooling, providing year-round temperature management.
The operating water temperature range is:
-
Heating: 9–40°C
-
Cooling: 9–35°C
This makes the system suitable for residential pools where water temperature needs to be adjusted according to season and user preference.
Reliable Performance in Different Conditions
The unit is designed to operate with ambient temperatures from -7°C to 43°C, supporting pool heating across a broad range of outdoor conditions.
Its variable-speed operation helps adapt the heating output to changing environmental and pool conditions.
Titanium Heat Exchanger for Pool Water
The heat exchanger uses a spiral titanium tube in a PVC shell, providing reliable heat transfer and strong resistance for swimming pool applications.
Titanium construction is particularly suitable for pool water environments and helps support long-term system performance.
Low-Noise Operation
Depending on the model, sound pressure is approximately 44–57 dB(A) at 1m, while operation at 50% capacity is around 45–49 dB(A).
The inverter system allows the compressor to adjust its output according to demand, helping avoid unnecessary high-capacity operation during normal pool maintenance.
Durable ABS Outdoor Casing
The heat pump features a black ABS plastic casing designed for outdoor installation.
The lightweight and corrosion-resistant housing provides practical protection for poolside applications while maintaining a clean appearance suitable for residential environments.
OEM & Project Supply
We provide OEM/ODM and bulk supply for pool equipment distributors, installers, contractors, and heating solution providers.
Contact us for R32 inverter pool heat pump specifications, model selection, OEM customization, wholesale pricing, and project support.
| Model / Specifications | PW070-KZXYC-H | PW080-KZXYC-H | PW060-KZXYC-H | PW080-KZXYC-H | |
|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 60~120 | 70~130 | 60~110 | 70~130 |
| Operating air temperature (°C) | -7~43°C | ||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | |||||
| Heating capacity (kW) | 28.0~5.6 | 32.5~6.5 | 24.00~4.80 | 32.5~6.5 | |
| Heating capacity (Btu) | 95500~19100 | 110900~22100 | 81600~16320 | 110900~22100 | |
| Consumed power (kW) | 4.75~0.37 | 5.42~0.43 | 4.00~0.32 | 5.42~0.43 | |
| COP | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | |
| COP at 50% capacity | 11 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | |||||
| Heating capacity (kW) | 21.8~4.36 | 25.4~5.07 | 18.7~3.42 | 25.4~5.07 | |
| Heating capacity (Btu) | 74380~14880 | 86665~17300 | 63580~11630 | 86665~17300 | |
| Consumed power (kW) | 4.54~0.62 | 5.29~0.72 | 3.89~0.49 | 5.29~0.72 | |
| COP | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | |||||
| Cooling capacity (kW) | 13.8 | 15.6 | 11.8 | 15.6 | |
| General Specifications | |||||
| Sound pressure at 1m | dB(A) | 45~56 | 45~57 | 44~54 | 45~57 |
| Sound pressure of 50% capacity at 1m | dB(A) | 48 | 49 | 45 | 49 |
| Sound pressure at 10m | dB(A) | 26~34 | 26~35 | 25~32 | 26~35 |
| Heat exchanger | Spiral titanium tube in PVC shell | ||||
| Casing | ABS plastic casing black color | ||||
| Refrigerant | R32 | ||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | 220V~230V/1 Ph/50Hz~60Hz | 380V/3 Ph/50Hz/60Hz | 380V/3 Ph/50Hz/60Hz | |
| Water connection (mm) | Φ50 | ||||
| Rated input current at air 15°C (A) | 20.8~2.8 | 24.2~3.3 | 6.9~0.9 | 9.4~1.3 | |
| Advised water flux (m³/h) | 10~14 | 12~16 | 9~12 | 12~16 | |
| Water pressure drop (max) | kPa | 20 | 25 | 15 | 25 |
| Net weight / Gross weight (kg) | 90/105 | 93/108 | 80/94 | 93/108 | |
| Product size (mm) | 1156X433X905 | 1156X433X905 | 1125X416X765 | 1156X433X905 | |
| Operating water temperature (°C) | Heating | 9~40°C | |||
| Operating water temperature (°C) | Cooling | 9~35°C | |||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. |
|||||