Residential R32 DC Inverter Heat Pump For Pool Quiet Pro Pool Heater
Quiet R32 DC Inverter Pool Heat Pump The Quiet R32 DC Inverter Pool Heat Pump is designed for residential swimming pools that require reliable temperature control with low operating noise. It combines variable-speed inverter technology with an optimized heat exchange system to deliver steady heating ...
DC Inverter Heat Pump For Pool
,Residential Inverter Heat Pump For Pool
Quiet R32 DC Inverter Pool Heat Pump
The Quiet R32 DC Inverter Pool Heat Pump is designed for residential swimming pools that require reliable temperature control with low operating noise. It combines variable-speed inverter technology with an optimized heat exchange system to deliver steady heating performance for private pools and villa projects.
Using R32 refrigerant, the unit transfers heat from ambient air to pool water while adjusting its output according to actual heating demand. This allows the system to operate more efficiently under different pool conditions.
Variable-Speed Pool Heating
The DC Inverter compressor automatically changes its operating speed based on the required heating capacity.
Instead of frequently starting and stopping at full power, the system can maintain a lower output once the desired water temperature is approached.
Benefits include:
- Stable pool water temperature
- Improved part-load efficiency
- Reduced energy consumption
- Fewer compressor start-stop cycles
- Smooth heating operation
Low-Noise Operation
The Quiet Pro Series is developed for residential environments where pool equipment may be installed close to living spaces.
The optimized compressor and fan operation helps keep operating noise low, making the unit suitable for villa pools, private gardens, patios, and residential leisure areas.
Efficient Air-to-Water Heat Exchange
The heat pump captures thermal energy from the surrounding air and transfers it to the pool water through the heat exchanger.
This air-source heating process provides an energy-efficient approach to maintaining pool temperature and can reduce the need for conventional electric heating.
The optimized heat exchange system supports stable performance during regular pool operation.
Modern Design for Residential Pools
The equipment is designed not only for heating performance but also for integration into modern outdoor environments.
Its streamlined appearance works well with:
- Villa swimming pools
- Private residential pools
- Garden pools
- Luxury homes
- Residential pool renovation projects
The clean design allows the heat pump to fit naturally alongside other pool equipment.


| Model / Specifications | PW010-KZXYC-H | PW015-KZXYC-H | PW020-KZXYC-H | PW030-KZXYC-H | PW040-KZXYC-H | PW050-KZXYC-H | PW060-KZXYC-H | |
|---|---|---|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 15~30 | 20~40 | 25~50 | 30~60 | 40~75 | 55~100 | 55~100 |
| Operating air temperature (°C) | -7~43°C | |||||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | ||||||||
| Heating capacity (kW) | 7.50~1.92 | 9.50~2.10 | 11.00~2.50 | 14.00~3.15 | 17.00~3.75 | 20.00~4.00 | 24.00~4.80 | |
| Heating capacity (Btu) | 25500~6528 | 32300~7140 | 37400~8500 | 47600~10710 | 57800~13090 | 68000~13600 | 81600~16320 | |
| Consumed power (kW) | 1.15~0.13 | 1.46~0.14 | 1.83~0.17 | 2.15~0.21 | 2.62~0.25 | 3.33~0.27 | 4.00~0.32 | |
| COP | 6.5~14.8 | 6.5~15.0 | 6.0~14.7 | 6.5~15.0 | 6.5~15.0 | 6.0~14.8 | 6.0~15.0 | |
| COP at 50% capacity | 10.5 | 11 | 11 | 10.5 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | ||||||||
| Heating capacity (kW) | 5.80~1.42 | 7.2~1.50 | 8.5~1.65 | 10.7~2.40 | 13.0~2.65 | 15.6~2.85 | 18.7~3.42 | |
| Heating capacity (Btu) | 19720~4828 | 24480~5100 | 28900~5610 | 36380~8160 | 44200~9010 | 53040~9690 | 63580~11630 | |
| Consumed power (kW) | 1.15~0.20 | 1.43~0.21 | 1.77~0.23 | 2.12~0.34 | 2.58~0.36 | 3.25~0.40 | 3.89~0.49 | |
| COP | 5.0~7.1 | 5.0~7.2 | 4.8~7.2 | 5.0~7.1 | 5.0~7.4 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | ||||||||
| Cooling capacity (kW) | 4 | 5.2 | 6 | 7.2 | 8.6 | 10.1 | 11.8 | |
| General Specifications | ||||||||
| Sound pressure at 1m | dB(A) | 38~48 | 38~48 | 40~50 | 42~51 | 43~52 | 43~53 | 44~54 |
| Sound pressure of 50% capacity at 1m | dB(A) | 40 | 40 | 41 | 43 | 44 | 44 | 45 |
| Sound pressure at 10m | dB(A) | 18~25 | 18~25 | 19~26 | 22~27 | 23~30 | 24~31 | 25~32 |
| Heat exchanger | Spiral titanium tube in PVC shell | |||||||
| Casing | ABS plastic casing black color | |||||||
| Refrigerant | R32 | |||||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | |||||||
| Water connection (mm) | Φ50 | |||||||
| Rated input current at air 15°C (A) | 5.1~0.9 | 6.3~0.9 | 7.8~1.0 | 9.3~1.5 | 11.3~1.6 | 14.3~1.8 | 17.8~2.3 | |
| Advised water flux (m³/h) | 2~4 | 2~4 | 3~5 | 4~6 | 6~9 | 8~10 | 9~12 | |
| Water pressure drop (max) | kPa | 5 | 5 | 8 | 10 | 12 | 15 | 15 |
| Net weight / Gross weight (kg) | 56/68 | 56/68 | 58/70 | 64/76 | 72/86 | 72/86 | 80/94 | |
| Product size (mm) | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1125X416X765 | 1125X416X765 | 1125X416X765 | |
| Operating water temperature (°C) | Heating | 9~40°C | ||||||
| Operating water temperature (°C) | Cooling | 9~35°C | ||||||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. |
||||||||