PV Direct Drive Quiet Pool Heat Pump R32 DC Inverter Energy Save Heat Pump
R32 DC Inverter Pool Heat Pump for Residential Swimming Pools The R32 DC Inverter Pool Heat Pump is developed for residential swimming pools with water capacities from 15 to 130m³. It provides flexible heating performance for private pools, villa pools, and other residential swimming pool applicatio...
PV Direct Drive Quiet Pool Heat Pump
,Quiet Pool Heat Pump R32
,DC Inverter Energy Save Heat Pump
R32 DC Inverter Pool Heat Pump for Residential Swimming Pools
The R32 DC Inverter Pool Heat Pump is developed for residential swimming pools with water capacities from 15 to 130m³. It provides flexible heating performance for private pools, villa pools, and other residential swimming pool applications.
Using DC Inverter technology, the heat pump varies compressor speed according to the required heating output. This helps the system respond to changing pool conditions, maintain a more consistent water temperature, and improve energy efficiency during everyday operation.
Designed for Different Pool Sizes
With a recommended capacity range of 15–130m³, the unit can be selected for different residential pool sizes and heating requirements.
It is suitable for:
- Villa swimming pools
- Private residential pools
- Garden pools
- Leisure swimming pools
- New pool installations
- Pool heating replacement projects
Variable-Speed Inverter Operation
The inverter compressor adjusts its output instead of continuously operating at a fixed capacity. When the pool requires less heat, the system can reduce its operating output; when additional heating is needed, it increases capacity accordingly.
This operating method helps provide:
- Stable pool water temperature
- Efficient heating performance
- Reduced unnecessary power consumption
- Fewer compressor start-stop cycles
- Smoother operation
Quiet Performance for Residential Use
With operating noise as low as 40 dB(A), the Quiet Pro Series is designed for environments where pool equipment is located near homes, gardens, or outdoor leisure areas.
The low-noise design helps reduce disturbance while the heat pump maintains the desired pool temperature.
Optimized Front Airflow
The unit features an optimized front airflow structure that supports effective air circulation through the heat exchange system.
This configuration helps improve heat transfer and provides greater flexibility when arranging the pool equipment area.
Durable ABS Outdoor Housing
A corrosion-resistant ABS casing protects the heat pump during outdoor installation and provides a durable exterior for residential pool environments.
The streamlined housing also gives the equipment a clean appearance that fits naturally into modern pool surroundings.
PV Direct Drive Compatible
The heat pump supports PV Direct Drive, allowing it to be integrated with a compatible photovoltaic power system.
By utilizing available solar electricity for pool heating, users can make better use of renewable energy and reduce dependence on conventional grid electricity.
| Model / Specifications | PW010-KZXYC-H | PW015-KZXYC-H | PW020-KZXYC-H | PW030-KZXYC-H | PW040-KZXYC-H | PW050-KZXYC-H | PW060-KZXYC-H | |
|---|---|---|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 15~30 | 20~40 | 25~50 | 30~60 | 40~75 | 55~100 | 55~100 |
| Operating air temperature (°C) | -7~43°C | |||||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | ||||||||
| Heating capacity (kW) | 7.50~1.92 | 9.50~2.10 | 11.00~2.50 | 14.00~3.15 | 17.00~3.75 | 20.00~4.00 | 24.00~4.80 | |
| Heating capacity (Btu) | 25500~6528 | 32300~7140 | 37400~8500 | 47600~10710 | 57800~13090 | 68000~13600 | 81600~16320 | |
| Consumed power (kW) | 1.15~0.13 | 1.46~0.14 | 1.83~0.17 | 2.15~0.21 | 2.62~0.25 | 3.33~0.27 | 4.00~0.32 | |
| COP | 6.5~14.8 | 6.5~15.0 | 6.0~14.7 | 6.5~15.0 | 6.5~15.0 | 6.0~14.8 | 6.0~15.0 | |
| COP at 50% capacity | 10.5 | 11 | 11 | 10.5 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | ||||||||
| Heating capacity (kW) | 5.80~1.42 | 7.2~1.50 | 8.5~1.65 | 10.7~2.40 | 13.0~2.65 | 15.6~2.85 | 18.7~3.42 | |
| Heating capacity (Btu) | 19720~4828 | 24480~5100 | 28900~5610 | 36380~8160 | 44200~9010 | 53040~9690 | 63580~11630 | |
| Consumed power (kW) | 1.15~0.20 | 1.43~0.21 | 1.77~0.23 | 2.12~0.34 | 2.58~0.36 | 3.25~0.40 | 3.89~0.49 | |
| COP | 5.0~7.1 | 5.0~7.2 | 4.8~7.2 | 5.0~7.1 | 5.0~7.4 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | ||||||||
| Cooling capacity (kW) | 4 | 5.2 | 6 | 7.2 | 8.6 | 10.1 | 11.8 | |
| General Specifications | ||||||||
| Sound pressure at 1m | dB(A) | 38~48 | 38~48 | 40~50 | 42~51 | 43~52 | 43~53 | 44~54 |
| Sound pressure of 50% capacity at 1m | dB(A) | 40 | 40 | 41 | 43 | 44 | 44 | 45 |
| Sound pressure at 10m | dB(A) | 18~25 | 18~25 | 19~26 | 22~27 | 23~30 | 24~31 | 25~32 |
| Heat exchanger | Spiral titanium tube in PVC shell | |||||||
| Casing | ABS plastic casing black color | |||||||
| Refrigerant | R32 | |||||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | |||||||
| Water connection (mm) | Φ50 | |||||||
| Rated input current at air 15°C (A) | 5.1~0.9 | 6.3~0.9 | 7.8~1.0 | 9.3~1.5 | 11.3~1.6 | 14.3~1.8 | 17.8~2.3 | |
| Advised water flux (m³/h) | 2~4 | 2~4 | 3~5 | 4~6 | 6~9 | 8~10 | 9~12 | |
| Water pressure drop (max) | kPa | 5 | 5 | 8 | 10 | 12 | 15 | 15 |
| Net weight / Gross weight (kg) | 56/68 | 56/68 | 58/70 | 64/76 | 72/86 | 72/86 | 80/94 | |
| Product size (mm) | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1125X416X765 | 1125X416X765 | 1125X416X765 | |
| Operating water temperature (°C) | Heating | 9~40°C | ||||||
| Operating water temperature (°C) | Cooling | 9~35°C | ||||||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. |
||||||||