Quality Structural Bond Teflon Underfloor Heating Mat 150W 4-5mm Tile Warming factory
Quality Structural Bond Teflon Underfloor Heating Mat 150W 4-5mm Tile Warming factory

Structural Bond Teflon Underfloor Heating Mat 150W 4-5mm Tile Warming

Structural Bond Teflon Underfloor Heating Mat 150W 4-5mm Tile Warming
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
ATIV-150
Trading Properties
MOQ
3 pcs
Unit Price
$20-190
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

Twin Conductor Teflon Heating Mat: 150W/m², 4-5mm thin, 70°C max. Features aluminum foil shielding, 300g/m² fiberglass mesh with double-sided tape for easy installation. Ideal for underfloor heating in homes and commercial spaces. OEM and custom specifications available for bulk supply.

Product Details
Highlight:

Structural Bond Teflon Mat

,

4-5mm Mortar Embedded Mat

,

Tile Stone Bond Warming

Fiberglass Mesh: 300g/m2 With Double-sided Tape Back
Thickness: 4-5mm
Power Density: 150W/m2
Max. Working Temp.: 70°C
Cold Lead: 1*2.5m(2mm2)
Cable Structure: Twin Conductor
Cable Outer Diameter: 4mm
Cable Shielding: Aluminum Foil + Copper Wire
Product Description
Twin-Conductor Teflon Heating Mat
Heavy-Duty Fluoropolymer Radiant Mat for Tile & Stone Installations

Engineered specifically for thin-bed mortar and self-leveling floor assemblies, our Twin-Conductor Teflon Heating Mat combines a high-tensile fluoropolymer heating cable with an open-weave fiberglass grid. It delivers rapid, uniform floor warming while maintaining full structural bond strength between the subfloor and the finished tile or stone.

Built to Survive Jobsite Abuse & Mortar Curing

On active construction and remodel sites, heating cables are exposed to trowel scraping, foot traffic, and high-alkaline cement curing before the tile is ever laid. Our Teflon construction eliminates jobsite vulnerability:

  • High Mechanical Crush & Abrasion Resistance: Tough fluoropolymer (PTFE/FEP) primary insulation and heavy-duty outer jacket withstand accidental trowel nicks and foot traffic during tile setting.
  • 200 °C+ Continuous Thermal Rating: Prevents thermal degradation even under thick natural stone, heavy bathmats, or low-airflow vanity toe-kicks.
  • Open-Weave Mortar Pass-Through: The wide-aperture fiberglass mesh allows thin-set adhesive to flow freely through the grid, ensuring a 100% solid bond between subfloor and tile—preventing hollow spots or cracked grout lines.
Simplified Rough-In & Code-Compliant Safety

Designed to pass electrical inspections on the first visit and minimize wall-chasing labor:

  • Single Cold-Lead Termination: Twin-conductor internal geometry eliminates the need to loop the cable back to the wall box—only one power lead enters the thermostat conduit.
  • 360° Grounded Metallic Screen: Continuous tinned-copper/aluminum earth braid provides complete fault-current protection for wet-room compliance (bathrooms, walk-in showers, and spa areas).
  • EMF-Cancelled Operation: Parallel opposing currents within the twin-core cable neutralize electromagnetic emissions for bedrooms, living areas, and commercial spaces.
Fast Layout Control Without Loose-Wire Guesswork
  • Factory-Calibrated Spacing: Pre-fixed cable loops maintain exact center-to-center spacing across the entire roll, guaranteeing even heat distribution without cold zones.
  • Cut-and-Pivot Grid: Installers can snip the fiberglass backing mesh (without touching the heating wire) to turn 90°, reverse direction, or contour around floor drains and toilets in seconds.
  • Low-Profile ~3.5 mm – 4.0 mm Build: Sits cleanly inside standard tile adhesive or leveling compound without raising finished floor thresholds.
Where It Performs Best
  • Bathroom & Wet-Area Remodels: Eliminates cold tile shock and speeds up floor evaporation after shower use.
  • Kitchens, Entryways & Sunrooms: Converts high-traffic ceramic, porcelain, and slate floors into comfortable radiant heat zones.
  • Multi-Unit Residential & Hotels: Provides independent, thermostat-controlled room heating with zero boilers, pumps, or water leakage liabilities.
Contractor & Distributor Supply Specs

Engineered for electrical wholesalers, tile distributors, and HVAC project suppliers:

  • Standard Heat Densities: 100 W/m² (engineered wood/laminate & low-loss builds), 150 W/m² (standard tile & residential rooms), 200 W/m² (bathrooms, conservatories & high heat-loss substrates).
  • Electrical Ratings: 110V–120V or 220V–240V, 50/60 Hz.
  • Roll Dimensions: 0.5 m standard width across pre-terminated lengths (1 m² to 15 m²+ per mat).
  • Supply & OEM Options: Supplied as bulk contractor rolls or private-label retail kits (including heating mat, NTC floor sensor, flexible sensor conduit, and programmable/Wi-Fi thermostat).

Contact our technical team for resistance tables, layout guidelines, and distributor pricing.

Model Selection & Technical Data
No. Voltage (V) Power (W) Resistance (Ω) Width (m) Length (m) Heating Area (m²)
ATV1500075C 230 75 705.30 0.50 1 0.50
ATV1500150C 230 150 352.70 0.50 2 1.00
ATV1500225C 230 225 235.10 0.50 3 1.50
ATV1500300C 230 300 176.30 0.50 4 2.00
ATV1500375C 230 375 141.10 0.50 5 2.50
ATV1500450C 230 450 117.60 0.50 6 3.00
ATV1500525C 230 525 100.80 0.50 7 3.50
ATV1500600C 230 600 88.20 0.50 8 4.00
ATV1500675C 230 675 78.40 0.50 9 4.50
ATV1500750C 230 750 70.50 0.50 10 5.00
ATV1500825C 230 825 64.10 0.50 11 5.50
ATV1500900C 230 900 58.80 0.50 12 6.00
ATV1500975C 230 975 54.30 0.50 13 6.50
ATV1501050C 230 1,050 50.40 0.50 14 7.00
ATV1501125C 230 1,125 47.00 0.50 15 7.50
ATV1501200C 230 1,200 44.10 0.50 16 8.00
ATV1501275C 230 1,275 41.50 0.50 17 8.50
ATV1501350C 230 1,350 39.20 0.50 18 9.00
ATV1501425C 230 1,425 37.10 0.50 19 9.50
ATV1501500C 230 1,500 35.30 0.50 20 10.00
ATV1501575C 230 1,575 33.60 0.50 21 10.50
ATV1501650C 230 1,650 32.10 0.50 22 11.00
ATV1501725C 230 1,725 30.70 0.50 23 11.50
ATV1501800C 230 1,800 29.40 0.50 24 12.00

Custom wattages, voltages, and mat dimensions are available upon request. Contact our engineering team for resistance charts and technical datasheets.

Contact our sales engineering team for technical datasheets, resistance charts, and volume pricing.

Twin-conductor Teflon heating mat with fiberglass carrier mesh, showing thin cable profile and single cold-lead connection for underfloor heating installation
Twin-conductor Teflon heating mat with open-weave fiberglass carrier mesh and single cold-lead termination.