Direct Acting Underfloor Heating Mat 150W Slim Uniform Floor Warmth
Ultra-thin 3.5-4mm electric underfloor heating mat with twin conductor, aluminum foil shielding, and 300g/m2 fiberglass mesh. 150W/m2 for tile, wood, and renovation projects. OEM/ODM and bulk supply available.
Direct Acting Heating Mat
,Twin Conductor Mesh Mat
,Uniform Floor Warmth Kit
An ultra-thin, direct-acting electric heating mat engineered for installation directly within tile adhesive or self-leveling compound. It converts cold ceramic, stone, and engineered wood floors into responsive radiant heat emitters without increasing structural floor height.
Unlike storage heating systems buried deep in concrete screeds, this mat sits directly beneath the floor finish for immediate thermal transfer:
- Direct-Acting Heat Transfer: Positioned just millimeters under the finished surface, minimizing downward heat loss and reducing warm-up lag time.
- Negligible Elevation (~3.5 mm – 4.0 mm): The low-profile twin-conductor cable embeds cleanly into standard thin-set mortar, preserving existing door clearances and threshold levels.
- Uniform Wattage Density: Pre-set cable spacing on the carrier mesh guarantees consistent heat output per square meter, eliminating cold spots across the floor plane.
Engineered for structural versatility across new residential builds, commercial wet areas, and existing floor retrofits:
- Approved Subfloors: Concrete slabs, cement backer boards, insulated tile backer panels, and structurally sound existing ceramic tiles.
- Approved Floor Coverings: Porcelain, ceramic tile, natural stone, slate, terrazzo, and temperature-rated laminate or engineered hardwood (when installed within a self-leveling layer and paired with a floor-limiting thermostat).
- No-Demolition Retrofits: Can be bonded directly over existing tiled floors using polymer-modified tile adhesive, avoiding jackhammering, dust, and subfloor reconstruction.
Built for continuous thermal cycling and long-term durability inside alkaline mortar environments:
- Twin-Conductor Heating Core: Features both supply and return conductors within a single cable, requiring only one cold-lead connection to the wall junction box.
- Alkali-Resistant Insulation: Primary fluoropolymer/XLPE conductor insulation and tough outer PVC/fluoropolymer jacket resist chemical degradation from cementitious adhesives.
- 360° Grounded Metal Shield: Full metallic earth braid provides mechanical crush protection and ensures safe operation in high-moisture zones such as walk-in showers and bathrooms.
- Reinforced Self-Adhesive Mesh: Open-weave fiberglass grid lays flat without curling and can be cut and pivoted on-site to fit around floor drains, vanities, and room perimeters.
Operates in conjunction with floor-sensing thermostats to balance thermal comfort and power consumption:
- NTC Floor Probe Regulation: A dedicated floor temperature sensor prevents thermal shock to delicate stone or wood finishes while maintaining exact surface temperatures.
- Zoned Energy Control: Enables independent room-by-room scheduling—heating high-use areas like bathrooms during morning and evening hours without running a central boiler.
Supplied for electrical wholesalers, tile distributors, and HVAC project contractors:
- Standard Output Densities: 100 W/m² (wood/laminate & well-insulated spaces), 150 W/m² (standard tile & living areas), 200 W/m² (bathrooms, conservatories & high heat-loss zones).
- Voltage Options: 110V–120V or 220V–240V, 50/60Hz.
- Standard Mat Width: 0.5 m (available in pre-terminated lengths from 1 m² to 15 m²+).
- Supply Formats: Individual contractor rolls or retail-ready kits (mat, NTC floor sensor, sensor conduit, and programmable/Wi-Fi thermostat) with full OEM/ODM private-label support.
Contact our technical sales team for wiring diagrams, heat-loss sizing charts, and volume quotations.
| Model | No. | Voltage (V) | Power (W) | Resistance (Ω) | Width (m) | Length (m) | Heating Area (m²) |
|---|---|---|---|---|---|---|---|
| ATIF-150 | AT1500150C | 230 | 150 | 352.7 | 0.5 | 2.0 | 1.0 |
| ATIF-150 | AT1500225C | 230 | 225 | 235.1 | 0.5 | 3.0 | 1.5 |
| ATIF-150 | AT1500300C | 230 | 300 | 176.3 | 0.5 | 4.0 | 2.0 |
| ATIF-150 | AT1500375C | 230 | 375 | 141.1 | 0.5 | 5.0 | 2.5 |
| ATIF-150 | AT1500450C | 230 | 450 | 117.6 | 0.5 | 6.0 | 3.0 |
| ATIF-150 | AT1500525C | 230 | 525 | 100.8 | 0.5 | 7.0 | 3.5 |
| ATIF-150 | AT1500600C | 230 | 600 | 88.2 | 0.5 | 8.0 | 4.0 |
| ATIF-150 | AT1500725C | 230 | 725 | 73.0 | 0.5 | 9.7 | 4.8 |
| ATIF-150 | AT1500900C | 230 | 900 | 58.8 | 0.5 | 12.0 | 6.0 |
| ATIF-150 | AT1501050C | 230 | 1050 | 50.4 | 0.5 | 14.0 | 7.0 |
| ATIF-150 | AT1501200C | 230 | 1200 | 44.1 | 0.5 | 16.0 | 8.0 |
| ATIF-150 | AT1501350C | 230 | 1350 | 39.2 | 0.5 | 18.0 | 9.0 |
| ATIF-150 | AT1501500C | 230 | 1500 | 35.3 | 0.5 | 20.0 | 10.0 |
| ATIF-150 | AT1501800C | 230 | 1800 | 29.4 | 0.5 | 24.0 | 12.0 |
All models operate at 230 V with a 0.5 m mat width. Custom wattages, voltages, and dimensions are available for volume OEM/ODM orders.

Electric underfloor heating mat with pre-spaced twin-conductor cable on self-adhesive fiberglass mesh, shown installed beneath floor tile.
Need project support? Contact our technical sales team for wiring diagrams, heat-loss sizing charts, and volume quotations.