Quality Direct Acting Underfloor Heating Mat 150W Slim Uniform Floor Warmth factory
Quality Direct Acting Underfloor Heating Mat 150W Slim Uniform Floor Warmth factory

Direct Acting Underfloor Heating Mat 150W Slim Uniform Floor Warmth

Direct Acting Underfloor Heating Mat 150W Slim Uniform Floor Warmth
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
ATIF-150
Trading Properties
MOQ
3 pcs
Unit Price
$20-190
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

Ultra-thin 3.5-4mm electric underfloor heating mat with twin conductor, aluminum foil shielding, and 300g/m2 fiberglass mesh. 150W/m2 for tile, wood, and renovation projects. OEM/ODM and bulk supply available.

Product Details
Highlight:

Direct Acting Heating Mat

,

Twin Conductor Mesh Mat

,

Uniform Floor Warmth Kit

Cold Lead: 1*2.5m(2mm2)
Cable Shielding: Aluminum Foil + Copper Wire
Max. Working Temp.: 120°C
Thickness: 3.5-4mm
Cable Outer Diameter: 2.8mm
Cable Structure: Twin Conductor
Power Density: 130W/m2, 150W/m2
Fiberglass Mesh: 300g/m2 With Double-sided Tape Back
Product Description
Electric Heating Mat

An ultra-thin, direct-acting electric heating mat engineered for installation directly within tile adhesive or self-leveling compound. It converts cold ceramic, stone, and engineered wood floors into responsive radiant heat emitters without increasing structural floor height.

Thermal Performance & Floor Build-Up

Unlike storage heating systems buried deep in concrete screeds, this mat sits directly beneath the floor finish for immediate thermal transfer:

  • Direct-Acting Heat Transfer: Positioned just millimeters under the finished surface, minimizing downward heat loss and reducing warm-up lag time.
  • Negligible Elevation (~3.5 mm – 4.0 mm): The low-profile twin-conductor cable embeds cleanly into standard thin-set mortar, preserving existing door clearances and threshold levels.
  • Uniform Wattage Density: Pre-set cable spacing on the carrier mesh guarantees consistent heat output per square meter, eliminating cold spots across the floor plane.
Subfloor & Finish Compatibility

Engineered for structural versatility across new residential builds, commercial wet areas, and existing floor retrofits:

  • Approved Subfloors: Concrete slabs, cement backer boards, insulated tile backer panels, and structurally sound existing ceramic tiles.
  • Approved Floor Coverings: Porcelain, ceramic tile, natural stone, slate, terrazzo, and temperature-rated laminate or engineered hardwood (when installed within a self-leveling layer and paired with a floor-limiting thermostat).
  • No-Demolition Retrofits: Can be bonded directly over existing tiled floors using polymer-modified tile adhesive, avoiding jackhammering, dust, and subfloor reconstruction.
Cable Architecture & Electrical Integrity

Built for continuous thermal cycling and long-term durability inside alkaline mortar environments:

  • Twin-Conductor Heating Core: Features both supply and return conductors within a single cable, requiring only one cold-lead connection to the wall junction box.
  • Alkali-Resistant Insulation: Primary fluoropolymer/XLPE conductor insulation and tough outer PVC/fluoropolymer jacket resist chemical degradation from cementitious adhesives.
  • 360° Grounded Metal Shield: Full metallic earth braid provides mechanical crush protection and ensures safe operation in high-moisture zones such as walk-in showers and bathrooms.
  • Reinforced Self-Adhesive Mesh: Open-weave fiberglass grid lays flat without curling and can be cut and pivoted on-site to fit around floor drains, vanities, and room perimeters.
Temperature Regulation & System Control

Operates in conjunction with floor-sensing thermostats to balance thermal comfort and power consumption:

  • NTC Floor Probe Regulation: A dedicated floor temperature sensor prevents thermal shock to delicate stone or wood finishes while maintaining exact surface temperatures.
  • Zoned Energy Control: Enables independent room-by-room scheduling—heating high-use areas like bathrooms during morning and evening hours without running a central boiler.
Technical Specifications & B2B Supply

Supplied for electrical wholesalers, tile distributors, and HVAC project contractors:

  • Standard Output Densities: 100 W/m² (wood/laminate & well-insulated spaces), 150 W/m² (standard tile & living areas), 200 W/m² (bathrooms, conservatories & high heat-loss zones).
  • Voltage Options: 110V–120V or 220V–240V, 50/60Hz.
  • Standard Mat Width: 0.5 m (available in pre-terminated lengths from 1 m² to 15 m²+).
  • Supply Formats: Individual contractor rolls or retail-ready kits (mat, NTC floor sensor, sensor conduit, and programmable/Wi-Fi thermostat) with full OEM/ODM private-label support.

Contact our technical sales team for wiring diagrams, heat-loss sizing charts, and volume quotations.

ATIF-150 Series — Standard Models (230 V, 0.5 m Mat Width)
ATIF-150 Series Technical Specifications
Model No. Voltage (V) Power (W) Resistance (Ω) Width (m) Length (m) Heating Area (m²)
ATIF-150 AT1500150C 230 150 352.7 0.5 2.0 1.0
ATIF-150 AT1500225C 230 225 235.1 0.5 3.0 1.5
ATIF-150 AT1500300C 230 300 176.3 0.5 4.0 2.0
ATIF-150 AT1500375C 230 375 141.1 0.5 5.0 2.5
ATIF-150 AT1500450C 230 450 117.6 0.5 6.0 3.0
ATIF-150 AT1500525C 230 525 100.8 0.5 7.0 3.5
ATIF-150 AT1500600C 230 600 88.2 0.5 8.0 4.0
ATIF-150 AT1500725C 230 725 73.0 0.5 9.7 4.8
ATIF-150 AT1500900C 230 900 58.8 0.5 12.0 6.0
ATIF-150 AT1501050C 230 1050 50.4 0.5 14.0 7.0
ATIF-150 AT1501200C 230 1200 44.1 0.5 16.0 8.0
ATIF-150 AT1501350C 230 1350 39.2 0.5 18.0 9.0
ATIF-150 AT1501500C 230 1500 35.3 0.5 20.0 10.0
ATIF-150 AT1501800C 230 1800 29.4 0.5 24.0 12.0

All models operate at 230 V with a 0.5 m mat width. Custom wattages, voltages, and dimensions are available for volume OEM/ODM orders.

Electric underfloor heating mat with pre-spaced twin-conductor cable on self-adhesive fiberglass mesh, shown installed beneath floor tile

Electric underfloor heating mat with pre-spaced twin-conductor cable on self-adhesive fiberglass mesh, shown installed beneath floor tile.

Need project support? Contact our technical sales team for wiring diagrams, heat-loss sizing charts, and volume quotations.