Quality Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water factory
Quality Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water factory

Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water

Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
PW300-DKZLRS-E
Trading Properties
MOQ
3 pcs
Unit Price
$7500-13000
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

Commercial R290 heat pump with Dual DC Inverter delivers 78°C water and ErP A+++ efficiency (SCOP 4.57). Stainless steel housing, IPX4, cascade up to 8 units, plus custom pumps and leak detection for B2B projects.

Product Details
Highlight:

R290 Commercial Heat Pump

,

78C Water Commercial R290 Heat Pump

,

R290 Heat Pump

Power Supply: 380V/3Ph/50-60Hz
Refrigerant: R290
IP Grade: IPX4
Type: Air Source Heat Pump
Housing Material: Stainless Steel
Application: Outdoor, Hotel, Commercial, Household
Product Description

Commercial R290 Dual DC Inverter Heat Pump System

The Commercial R290 Dual DC Inverter Heat Pump System is a high-performance, eco-friendly hydronic thermal energy unit designed for modern commercial heating, comfort cooling, and high-temperature domestic hot water applications. Built around zero-ODP, low-GWP natural R290 refrigerant (GWP = 3), the system integrates advanced Dual DC Inverter drive technology to deliver an outstanding ErP A+++ efficiency rating (at 35°C water flow) with a SCOP of 4.57. Capable of generating elevated water supply temperatures up to 78°C, the platform supports multi-unit cascade setups up to 8 units, automated thermal disinfection cycles, and versatile custom options including built-in circulation pumps, active leak detection, and external thermal source controls.

Architectural Differentiators and B2B Value Engineering
High-Temperature 78°C Hydronic Output and Hygiene Protocols

High-temperature commercial space heating and sanitary hot water networks demand elevated flow temperatures without sacrificing system COP. Producing hot water up to 78°C, the system connects directly to legacy high-temperature panel radiators, air handling units (AHUs), and large-capacity domestic hot water tanks. The integrated controller features an automated, timed high-temperature disinfection function, providing a chemical-free, energy-efficient defense against Legionella contamination in hospitality, educational, and healthcare facilities.

Dual DC Inverter Modulation and SCOP 4.57 Seasonal Efficiency

Unlike single-inverter or fixed-speed commercial units, the Dual DC Inverter system dynamically modulates both compressor speed and fan assembly in tandem. This precise capacity regulation tracks dynamic building thermal loads, avoids unnecessary start-stop power surges, maintains stable loop temperatures, and achieves an exceptional SCOP of 4.57, drastically lowering annual operating expenses (OPEX) for property developers and facility managers.

Fully Modular Control Topologies and Multi-Source Integration

To accommodate modern multi-energy commercial plant designs, the control architecture supports a wide array of system topologies:

  • Master-Slave Cascade: Link up to 8 units in a single networked array for scalable capacity matching and operational redundancy.
  • Smart Grid (SG) and Automated Load Shifting: Natively syncs with local utility tariff structures and photovoltaic (PV) generation systems.
  • External Thermal Interlocks: Dedicated inputs for managing auxiliary heat sources (such as peak-shaving gas boilers or solar thermal arrays) and central water storage tanks.
Customizable Hydraulic and Safety Configurations

Engineered to streamline site assembly and meet strict regional building safety codes, the unit offers factory-customizable hardware options:

  • Integrated Circulating Pumps: Built-in pump modules tailored to specific system flow and head requirements, minimizing external mechanical room piping.
  • Refrigerant Leak Sensors: Internal gas density monitoring sensors for active leak detection, safety isolation, and forced cabinet ventilation.
  • Quiet Night Mode: Automated noise-suppression profiles that adjust fan rpm and operating frequencies during nocturnal hours to comply with municipal acoustic ordinances.
Strategic Advantages for MEP Contractors and OEM Partners
  • Reduced Mechanical Room Footprint: Factory-integrated customizable pumps and internal control logic eliminate bulky external pump skids and simplify field plumbing layouts.
  • Streamlined Bidding and Tender Compliance: ErP A+++ rating, zero-ODP natural gas composition, and SG Smart Grid readiness fulfill core technical eligibility criteria for European clean-energy government grants and commercial tenders.
  • Remote Fleet Operations: The integrated IoT Cloud Management Platform allows service teams and facility operators to monitor operating parameters across multiple commercial properties, adjust heat curves remotely, and receive instant diagnostic alerts before site visits.

Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water

Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water

Gas Boiler Replacement Commercial R290 Heat Pump Runs 78C Water

Model PW150-DKZLRS-E PW300-DKZLRS-E
DHW Condition-Ambient Temp.(DB/WB):20/15°C,Water Temp.(In/Out):15/55°C
Heating Capacity Range (kW) 23.8~68 40.0~130
Heating Power Input Range(kW) 4.23~15.46 9.0~29.5
COP Range 4.46~5.62 4.4~5.5
Heated water output (L/H) 1462 2580
Heating Condition - Ambient Temp.(DB/WB):7/6°C,Water Temp.(In/Out):30/35°C
Heating Capacity Range (kW) 18.4~49.25 35.2~92
Heating Power Input Range(kW) 4.23~12.96 7.0~23.8
COP Range 3.8~4.3 3.86~5.02
Cooling Condition - Ambient Temp.(DB/WB):35/24°C,Water Temp.(In/Out):12/7°C
Cooling Capacity Range (kW) 13.8~34.5 25~66
Cooling Power Input Range (kW) 5.2~16.2 8.92~30.7
EER Range 2.12~2.65 2.15~2.8
ErP Level (35°C) A+++ A+++
ErP Level (55°C) A++ A++
Power supply 380V/3Ph/50-60Hz
Max. power input (kW) 20 40
Max. current (A) 32 64
Fuse or circuit breaker (A) 40 80
Wire diameter (mm²) 10mm² 22mm²
Diameter of pipe (mm) G1.5" G2"
Sound power level (dB(A)) ≤77 ≤85
Sound pressure level (dB(A)) 62 65
Water Flow(m3/h) 5.8 11.6
Water Pressure Drop (max) kPa 80 120
Net Weight (kg) 370 745
Body size(W*D*H) (mm) 1195×980×1900 2510×979×1882
Packing size(W*D*H)(Polywood) 1275*1060*2100 2560×1030×2000
IP Grade (Level of protection) IPX4
Refrigerant R290
Operation Ambient Temp. (°C) -25~43°C
Water outlet temperature (°C) 20~78°C(DHW )
Water outlet temperature (°C) 20~78°C(Heating)
Water outlet temperature (°C) 7~35°C(Cooling)
Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data.