Quality 8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control factory
Quality 8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control factory

8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control

8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
PW08-DKXLRE1-H8
Trading Properties
MOQ
3 pcs
Unit Price
$2500-5000
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

High-efficiency R290 monobloc heat pump with 8-unit cascade, -25°C operation, 75°C supply, and ≤35dB quietness. ERP A+++ rated, PV-ready, Modbus BMS compatible, and §14a EnWG compliant for maximum rebates. Sealed design saves plant room space.

Product Details
Highlight:

Cascade R290 Air Source Heat Pump

,

Cold Climate Air Source Heat Pump

,

PV Ready Air Source Heat Pump

Expansion Tank: 6L
Refrigerant: R290
IP Grade: IPX4
Color: Black
Noise: ≤35dB
Heating Capacity: 6kw-16kw
Type: Air Source Heat Pump
Series: H8 Helios Pro Series
Product Description
R290 Full DC Inverter High-Temperature Monobloc Heat Pump

The R290 Full DC Inverter High-Temperature Monobloc Heat Pump is an engineered hydronic system providing space heating, space cooling, and domestic hot water generation. Designed for demanding climates with stable performance down to -25°C, the unit combines variable-speed DC inverter technology with eco-friendly natural R290 refrigerant (GWP = 3). Capable of delivering up to 75°C supply water and supporting up to 8-unit cascade setups, it provides an adaptable, high-efficiency heating infrastructure for large villas, multi-family residences, and light commercial retrofits.

Technical Differentiation and Engineering Breakthroughs
Scalable 8-Unit Cascade Architecture for Flexible Capacity

Unlike fixed-capacity commercial heat pumps that require rigid system sizing, this series supports intelligent cascade networking for up to 8 units. System controllers dynamically distribute heating loads across the network based on real-time demand, reducing component wear and maintaining continuous operational redundancy for large residential complexes, hotels, and commercial facilities.

Two-Stage R290 Safety Protection System

While natural R290 offers superior thermal conductivity and low environmental impact, safety engineering is critical. This unit incorporates a specialized two-stage refrigerant leakage mitigation architecture. Advanced sensor arrays continuously monitor internal gas density, automatically isolating fluid lines and engaging active ventilation protocols in the event of an abnormal pressure variance.

Dynamic Temperature Curve Adaptation

To optimize seasonal performance, the integrated controller utilizes an intelligent temperature curve algorithm. By automatically adjusting water supply flow temperatures in response to real-time outdoor climate changes, the heat pump eliminates manual setpoint adjustments, lowers operational energy waste, and maintains consistent indoor thermal comfort.

High-Temperature Hydronic Compatibility (75°C Supply Water)

With a maximum supply water temperature of 75°C, the monobloc system seamlessly interfaces with existing high-temperature panel radiators as well as modern underfloor heating circuits. This eliminates the necessity for internal piping modifications during fossil-fuel boiler replacement projects.

Technical Specifications
  • Equipment Design: Sealed Outdoor Monoblock Architecture
  • Operating Modes: Space Heating, Space Cooling, Domestic Hot Water
  • Refrigerant Medium: Low-GWP Natural R290 (GWP = 3)
  • Safety Protocols: Integrated Two-Stage Leakage Protection Architecture
  • Seasonal Energy Efficiency: ERP A+++ Class (at 35°C and 55°C Outlet Water)
  • Max Outlet Water Temperature: 75°C
  • Low Ambient Operating Limit: Fully Functional Down to -25°C
  • System Sound Pressure: Down to 35 dB(A) at 1 Meter Range
  • Multi-Unit Networking: Up to 8 Units Cascade Management
  • Human-Machine Interface: 7-Inch Color Touch Controller with Mobile App WiFi
  • Regulatory & Protocol Support: German §14a EnWG Compliant, PV-Ready Port, BMS Modbus
Value Proposition for Project Developers and Engineers
  • Reduced Plant Room Requirements: Monoblock configuration houses all refrigerant components within the outdoor housing, saving valuable indoor utility space and simplifying field assembly.
  • Lower Project Risk: Cascade logic ensures system redundancy; if a single unit undergoes maintenance, the remaining units automatically scale output to maintain thermal delivery.
  • High Government Rebate Qualification: ERP A+++ efficiency ratings, zero-ODP natural gas composition, and §14a EnWG smart grid compatibility ensure full eligibility for clean energy financial subsidies across European jurisdictions.

8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control

8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control8 Unit Cascade PV Ready R290 Monobloc Heat Pump Modbus Control

Model Series
Parameter / Feature PW06 PW08 PW10 PW12 PW14 PW16
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 30/35°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.19 1.64 2.03 2.39 2.92 3.26
COP 5.04 4.89 4.92 5.03 4.80 4.90
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 47/55°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.93 2.63 3.12 3.58 4.35 5.06
COP 3.11 3.04 3.21 3.35 3.22 3.16
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.18 1.58 1.94 2.32 2.78 3.37
EER 5.08 5.06 5.15 5.18 5.03 4.75
Operating Ranges & Capacity Ratings
Heating Capacity Range (kW) 3.4~8.5 4.1~11.0 4.2~12.9 6.3~17.0 6.6~19.3 7.8~22.0
Heating Power Input Range (kW) 0.66~1.92 0.78~2.56 0.82~2.91 1.23~4.12 1.31~4.79 1.55~5.47
COP Range 4.43~5.26 4.30~5.26 4.43~5.12 4.13~5.12 4.03~5.04 4.02~5.03
DHW Condition - Ambient Temp.(DB/WB): 20/15°C, Water Temp.(In/Out): 15/55°C
Heating Capacity Range (kW) 4.6~9.5 5.8~12.0 6.0~13.3 7.7~18.0 8.0~19.5 9.3~23.0
Heating Power Input Range (kW) 0.88~2.07 1.13~2.79 1.15~2.78 1.88~3.98 1.56~4.53 1.82~5.35
COP Range 4.59~5.23 4.30~5.13 4.78~5.21 4.38~5.32 4.30~5.13 4.30~5.11
Heated Water Output (L/H) 205 258 285 365 419 494
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 12/7°C
Cooling Capacity Range (kW) 2.2~6.0 3.3~8.0 3.4~10.5 5.0~13.2 5.6~15.2 6.4~16.5
Cooling Power Input Range (kW) 0.62~1.93 0.88~2.59 0.9~3.25 1.49~4.52 1.42~4.81 1.93~5.79
EER Range 3.11~3.55 3.09~3.75 3.23~3.78 2.92~3.35 3.16~3.94 2.85~3.31
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C (Range)
Cooling Capacity Range (kW) 3.3~8.0 4.5~10.8 5.1~13.0 7.9~17.0 8.2~18.5 9.5~20.5
Cooling Power Input Range (kW) 0.59~1.88 0.80~2.51 0.84~2.78 1.40~3.72 1.42~4.20 1.76~5.06
EER Range 4.26~5.60 4.30~5.63 4.68~6.07 4.56~5.62 4.40~5.77 4.05~5.40
Energy Efficiency Ratings (ErP)
ErP Level (55°C) A+++ A+++ A+++ A+++ A+++ A+++
ErP Level (35°C) A+++ A+++ A+++ A+++ A+++ A+++
Electrical & Hydraulic Specifications
Power Supply 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz
Max. Power Input (kW) 3.2+3.0 4.2+3.0 5.0+3.0 5.8+3.0 6.7+3.0 8.3+3.0
Max. Current (A) 14.6+13.8 19.2+13.8 21.7+13.8 25.2+13.8 30.7+13.8 38.0+13.8
Water Flow (m³/h) 1.46 1.89 2.22 2.92 3.52 3.78
Water Pressure Drop (max) kPa 30 35 40 43 58 60
Diameter of Pipe (mm) DN25 DN25 DN25 DN25 DN32 DN32
Physical & Operating Specifications
Net Weight (kg) 128 165 170 178 182 190
Body Size (W*D*H) (mm) 1200×465×791 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065
IP Grade (Level of Protection) IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Refrigerant R290 R290 R290 R290 R290 R290
Expansion Tank (L) 6L 6L 6L 6L 6L 6L
Electric Heater 3kW 3kW 3kW 3kW 3kW 3kW
Operating Ambient Temp. (°C) -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C
Operating Water Temp. (°C) 25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
Note: The data above is for reference only, please refer to the nameplate on the unit for more specific data.