Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
Certificate
Available
PRODUCT MODEL
PW10-DKXLRE1-H8
Trading Properties
MOQ
3 pcs
Unit Price
$2500-5000
Payment Method
L/C,D/A,D/P,T/T
Supply Capacity
200pcs 30days
Product Summary

H8 Helios Pro R290 monoblock heat pump delivers 6-16kW heating, cooling and DHW with 75°C output for direct boiler replacement. Features Full DC Inverter, A+++ ERP rating, -25°C operation, 35dB silent mode, and §14a EnWG smart grid compliance for maximum EU subsidies.

Product Details
Highlight:

R290 Inverter Air Source Heat Pump

,

6kW Air Source Heat Pump

,

Villa Air Source Heat Pump

Series: H8 Helios Pro Series
Refrigerant: R290
Heating Capacity: 6kw-16kw
Color: Black
Noise: ≤35dB
Type: Air Source Heat Pump
Product Description
H8 Helios Pro Series R290 High Temperature Monoblock Heat Pump

The H8 Helios Pro Series is a high-performance R290 air-to-water heat pump engineered to deliver space heating, space cooling, and domestic hot water from a unified monoblock system. Designed specifically for modern residential standards and fossil-fuel boiler replacement projects, the unit utilizes Full DC Inverter technology to dynamically modulate capacity in response to real-time heating loads. Capable of generating up to 75°C outlet water temperatures and operating reliably in ambient conditions as low as -25°C, it provides a carbon-neutral alternative for residential heating upgrades across Europe and cold-climate regions.

Architectural Differentiators
Direct Boiler Replacement Without Piping Modifications

Conventional heat pumps often fail to satisfy the high temperature requirements of existing cast-iron or steel radiator systems, requiring expensive underfloor heating overhauls. The H8 delivers hot water up to 75°C, enabling homeowners and contractors to directly replace fossil-fuel boilers while retaining existing indoor hydronic radiators, drastically lowering total retrofit investment and labor time.

German EnWG Section 14a and Smart Grid Compliance

Built for modern European smart energy infrastructure, the system natively supports §14a EnWG requirements for active grid power management. Featuring integrated PV-ready controls and BMS Modbus protocols, the heat pump automatically prioritizes self-generated solar energy from photovoltaic systems, maximizing energy self-sufficiency and reducing grid dependence.

Eco-Conscious R290 Natural Gas Integration

Powered by ultra-low GWP R290 natural refrigerant (GWP = 3, ODP = 0), the H8 completely avoids the regulatory risks and phase-down quotas associated with synthetic F-gases. Combined with Full DC Inverter control, it complies with strict European eco-design regulations while maintaining long-term environmental sustainability.

Silent Five-Stage Acoustic Engineering

To resolve residential noise restrictions, the unit incorporates a dedicated five-stage acoustic barrier system around the compressor, fan assembly, and internal fluid pathways. Sound emission drops to as low as 35 dB(A) during silent mode, allowing flexible installation near property borders.

Technical Specifications
  • Equipment Classification: Monoblock Air-to-Water Heat Pump

  • Integrated Functions: Space Heating, Space Cooling, Domestic Hot Water

  • Refrigerant Agent: Eco-Friendly R290 Natural Gas

  • Energy Efficiency Standard: ERP A+++ Class (at 35°C and 55°C Water Outlet)

  • Maximum Water Supply Temperature: 75°C

  • Low Temperature Limit: Fully Functional Down to -25°C

  • Seasonal Performance Ratio: COP Exceeds 4.5

  • Acoustic Sound Rating: Down to 35 dB(A) via Specialized Acoustic Barriers

  • User Control Interface: 7-Inch Touchscreen Panel with Built-In WiFi Module

  • Grid Control and Automation Protocols: §14a EnWG Compliant, PV-Ready Logic, BMS Modbus

  • Defrosting Technology: AI Condition-Based Smart Defrost Logic

Installer and B2B Value Proposition
  • Streamlined Renovation Workflow: 75°C high-temperature water capability removes the necessity of replacing indoor heat emitters, making it an attractive proposal for HVAC retrofit contractors.

  • Maximum Government Subsidy Qualification: ERP A+++ energy certification, R290 zero-pollution rating, and §14a EnWG grid compatibility allow end-users to apply for maximum clean-energy financial incentives across European markets.

  • Open Integration Architecture: Native Modbus communication interfaces enable straightforward connection to third-party home energy management systems without proprietary software lock-in.

75°C Hot Water R290 Monobloc Heat Pump Keeps Existing Radiators

75°C Hot Water R290 Monobloc Heat Pump Keeps Existing Radiators75°C Hot Water R290 Monobloc Heat Pump Keeps Existing Radiators

Model Series
Parameter / Feature PW06 PW08 PW10 PW12 PW14 PW16
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 30/35°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.19 1.64 2.03 2.39 2.92 3.26
COP 5.04 4.89 4.92 5.03 4.80 4.90
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 47/55°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.93 2.63 3.12 3.58 4.35 5.06
COP 3.11 3.04 3.21 3.35 3.22 3.16
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.18 1.58 1.94 2.32 2.78 3.37
EER 5.08 5.06 5.15 5.18 5.03 4.75
Operating Ranges & Capacity Ratings
Heating Capacity Range (kW) 3.4~8.5 4.1~11.0 4.2~12.9 6.3~17.0 6.6~19.3 7.8~22.0
Heating Power Input Range (kW) 0.66~1.92 0.78~2.56 0.82~2.91 1.23~4.12 1.31~4.79 1.55~5.47
COP Range 4.43~5.26 4.30~5.26 4.43~5.12 4.13~5.12 4.03~5.04 4.02~5.03
DHW Condition - Ambient Temp.(DB/WB): 20/15°C, Water Temp.(In/Out): 15/55°C
Heating Capacity Range (kW) 4.6~9.5 5.8~12.0 6.0~13.3 7.7~18.0 8.0~19.5 9.3~23.0
Heating Power Input Range (kW) 0.88~2.07 1.13~2.79 1.15~2.78 1.88~3.98 1.56~4.53 1.82~5.35
COP Range 4.59~5.23 4.30~5.13 4.78~5.21 4.38~5.32 4.30~5.13 4.30~5.11
Heated Water Output (L/H) 205 258 285 365 419 494
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 12/7°C
Cooling Capacity Range (kW) 2.2~6.0 3.3~8.0 3.4~10.5 5.0~13.2 5.6~15.2 6.4~16.5
Cooling Power Input Range (kW) 0.62~1.93 0.88~2.59 0.9~3.25 1.49~4.52 1.42~4.81 1.93~5.79
EER Range 3.11~3.55 3.09~3.75 3.23~3.78 2.92~3.35 3.16~3.94 2.85~3.31
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C (Range)
Cooling Capacity Range (kW) 3.3~8.0 4.5~10.8 5.1~13.0 7.9~17.0 8.2~18.5 9.5~20.5
Cooling Power Input Range (kW) 0.59~1.88 0.80~2.51 0.84~2.78 1.40~3.72 1.42~4.20 1.76~5.06
EER Range 4.26~5.60 4.30~5.63 4.68~6.07 4.56~5.62 4.40~5.77 4.05~5.40
Energy Efficiency Ratings (ErP)
ErP Level (55°C) A+++ A+++ A+++ A+++ A+++ A+++
ErP Level (35°C) A+++ A+++ A+++ A+++ A+++ A+++
Electrical & Hydraulic Specifications
Power Supply 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz
Max. Power Input (kW) 3.2+3.0 4.2+3.0 5.0+3.0 5.8+3.0 6.7+3.0 8.3+3.0
Max. Current (A) 14.6+13.8 19.2+13.8 21.7+13.8 25.2+13.8 30.7+13.8 38.0+13.8
Water Flow (m³/h) 1.46 1.89 2.22 2.92 3.52 3.78
Water Pressure Drop (max) kPa 30 35 40 43 58 60
Diameter of Pipe (mm) DN25 DN25 DN25 DN25 DN32 DN32
Physical & Operating Specifications
Net Weight (kg) 128 165 170 178 182 190
Body Size (W*D*H) (mm) 1200×465×791 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065
IP Grade (Level of Protection) IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Refrigerant R290 R290 R290 R290 R290 R290
Expansion Tank (L) 6L 6L 6L 6L 6L 6L
Electric Heater 3kW 3kW 3kW 3kW 3kW 3kW
Operating Ambient Temp. (°C) -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C
Operating Water Temp. (°C) 25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)

Note: The data above is for reference only, please refer to the nameplate on the unit for more specific data.