Low Noise R32 DC Inverter Pool Heat Pump For Residential Pools
R32 Low Noise DC Inverter Pool Heat Pump for Residential PoolsThe R32 Low Noise DC Inverter Pool Heat Pump provides an efficient heating solution for residential swimming pools, combining variable-speed operation, low-noise performance, and modern pool heating technology.Designed for private pools, ...
R32 DC Inverter Pool Heat Pump
,Residential DC Inverter Pool Heat Pump
R32 Low Noise DC Inverter Pool Heat Pump for Residential Pools
The R32 Low Noise DC Inverter Pool Heat Pump provides an efficient heating solution for residential swimming pools, combining variable-speed operation, low-noise performance, and modern pool heating technology.
Designed for private pools, villa swimming pools, and residential leisure areas, the unit automatically adapts its heating output to changing pool conditions, helping maintain the desired water temperature with efficient operation.
Efficient Heating with Inverter Control
The DC Inverter compressor adjusts its operating speed according to the actual heating demand of the pool.
This variable-capacity operation allows the system to provide only the heating output required at a given time, helping improve efficiency and reduce unnecessary compressor cycling.
Benefits include:
- Stable pool water temperature
- Efficient part-load operation
- Reduced energy consumption
- Smooth compressor performance
- Flexible heating output
Low-Noise Pool Heating
A quieter heat pump can make a significant difference in residential pool environments.
The optimized compressor and fan system is designed for low-noise operation, making the unit suitable for installation near villas, gardens, patios, and other outdoor living spaces.
It provides reliable pool heating without creating excessive equipment noise during everyday operation.
Air-to-Water Heat Pump Technology
The system absorbs thermal energy from the surrounding air and transfers it to the swimming pool water through the heat exchanger.
This air-source pool heating technology provides an efficient alternative to traditional direct electric heating and is suitable for maintaining comfortable water temperatures across residential pool applications.
Designed for Residential Pool Environments
The streamlined housing combines practical outdoor performance with a modern appearance, making the heat pump suitable for different residential settings.
Typical applications include:
- Private swimming pools
- Villa pools
- Garden swimming pools
- Residential leisure pools
- Pool renovation projects
- New pool heating installations
Solar Energy Compatible
The heat pump supports solar energy integration, allowing it to be paired with a compatible photovoltaic power system.
Using available solar electricity for pool heating can help increase renewable energy utilization and reduce dependence on conventional grid power.
| Model / Specifications | PW070-KZXYC-H | PW080-KZXYC-H | PW060-KZXYC-H (3Ph) | PW080-KZXYC-H (3Ph) | |
|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 60~120 | 70~130 | 60~110 | 70~130 |
| Operating air temperature (°C) | -7~43°C | ||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | |||||
| Heating capacity (kW) | 28.0~5.6 | 32.5~6.5 | 24.00~4.80 | 32.5~6.5 | |
| Heating capacity (Btu) | 95500~19100 | 110900~22100 | 81600~16320 | 110900~22100 | |
| Consumed power (kW) | 4.75~0.37 | 5.42~0.43 | 4.00~0.32 | 5.42~0.43 | |
| COP | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | |
| COP at 50% capacity | 11 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | |||||
| Heating capacity (kW) | 21.8~4.36 | 25.4~5.07 | 18.7~3.42 | 25.4~5.07 | |
| Heating capacity (Btu) | 74380~14880 | 86665~17300 | 63580~11630 | 86665~17300 | |
| Consumed power (kW) | 4.54~0.62 | 5.29~0.72 | 3.89~0.49 | 5.29~0.72 | |
| COP | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | |||||
| Cooling capacity (kW) | 13.8 | 15.6 | 11.8 | 15.6 | |
| General Specifications | |||||
| Sound pressure at 1m | dB(A) | 45~56 | 45~57 | 44~54 | 45~57 |
| Sound pressure of 50% capacity at 1m | dB(A) | 48 | 49 | 45 | 49 |
| Sound pressure at 10m | dB(A) | 26~34 | 26~35 | 25~32 | 26~35 |
| Heat exchanger | Spiral titanium tube in PVC shell | ||||
| Casing | ABS plastic casing black color | ||||
| Refrigerant | R32 | ||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | 220V~230V/1 Ph/50Hz~60Hz | 380V/3 Ph/50Hz/60Hz | 380V/3 Ph/50Hz/60Hz | |
| Water connection (mm) | Φ50 | ||||
| Rated input current at air 15°C (A) | 20.8~2.8 | 24.2~3.3 | 6.9~0.9 | 9.4~1.3 | |
| Advised water flux (m³/h) | 10~14 | 12~16 | 9~12 | 12~16 | |
| Water pressure drop (max) | kPa | 20 | 25 | 15 | 25 |
| Net weight / Gross weight (kg) | 90/105 | 93/108 | 80/94 | 93/108 | |
| Product size (mm) | 1156X433X905 | 1156X433X905 | 1125X416X765 | 1156X433X905 | |
| Operating water temperature (°C) | Heating | 9~40°C | |||
| Operating water temperature (°C) | Cooling | 9~35°C | |||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. | |||||