Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology
R290 Full DC Inverter Monobloc Air Source Heat Pump – H8 Helios Pro Series The H8 Helios Pro Series is an advanced R290 air source heat pump designed to provide efficient heating, cooling, and domestic hot water from a single compact monobloc system. Powered by Full DC Inverter technology, the H8 ...
Residential Air Source Heat Pumps IPX4
,Cold Climate Residential Air Source Heat Pumps
,Full DC Inverter Air Source Heat Pump
The H8 Helios Pro Series is an advanced R290 air source heat pump designed to provide efficient heating, cooling, and domestic hot water from a single compact monobloc system.
Powered by Full DC Inverter technology, the H8 automatically adjusts its operating capacity according to actual heating demand. Combined with natural R290 refrigerant, high-temperature water output, and intelligent control, it provides an efficient and flexible solution for modern residential and commercial heating systems.
With operation down to -25°C and water outlet temperatures up to 75°C, the H8 is engineered for demanding climates and a wide range of heating applications.
The variable-speed compressor and fan continuously adjust the system output according to the required heating or cooling load.
This helps reduce unnecessary energy consumption while maintaining stable water temperatures and comfortable indoor conditions.
The H8 uses R290 refrigerant with GWP=3, supporting the transition toward more environmentally friendly heating technologies.
A two-stage refrigerant leakage protection system provides additional safety during operation.
The H8 can produce outlet water temperatures of up to 75°C, expanding its compatibility with different heating applications.
With a working temperature down to -25°C, the H8 is designed for cold-weather heating applications.
Its AI intelligent defrost system automatically manages defrost cycles to help maintain stable heating performance and minimize unnecessary interruptions.
The H8 achieves ERP A+++ efficiency at both 35°C and 55°C, making it suitable for both low-temperature and higher-temperature heating systems.
Advanced fan and compressor noise reduction technology keeps operating sound as low as 35 dB(A) at 1 meter.
This makes the system suitable for homes, villas, and other environments where low operating noise is important.
The H8 combines local controls with connected smart management functions.
The 7-inch touchscreen controller provides an intuitive interface for daily operation and system configuration.
The temperature curve function helps the system adapt its operation to changing heating requirements and outdoor conditions.
For projects requiring higher heating capacity, up to 8 H8 units can operate in cascade.
This allows the system to be expanded according to project requirements without relying on a single oversized unit.
Suitable for:
- Large residential properties
- Villas
- Apartment buildings
- Small commercial buildings
- Heating renovation projects
- Multi-zone heating systems
The H8 Helios Pro Series supports §14a EnWG-compliant operation, making it suitable for applicable German smart-grid applications.
Its smart control architecture allows the heat pump to work with modern energy management strategies and helps optimize electricity usage.
The H8 combines several functions in one system:
Heating + Cooling + DHW
This makes it a flexible alternative to traditional heating equipment while reducing the need for multiple independent systems.
Its monobloc configuration also simplifies system integration by keeping the refrigeration circuit within the outdoor unit.



| Model Series | ||||||
| Parameter / Feature | PW06 | PW08 | PW10 | PW12 | PW14 | PW16 |
| Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 30/35°C | ||||||
| Nominal Capacity (kW) | 6.0 | 8.0 | 10.0 | 12.0 | 14.0 | 16.0 |
| Nominal Power Input (kW) | 1.19 | 1.64 | 2.03 | 2.39 | 2.92 | 3.26 |
| COP | 5.04 | 4.89 | 4.92 | 5.03 | 4.80 | 4.90 |
| Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 47/55°C | ||||||
| Nominal Capacity (kW) | 6.0 | 8.0 | 10.0 | 12.0 | 14.0 | 16.0 |
| Nominal Power Input (kW) | 1.93 | 2.63 | 3.12 | 3.58 | 4.35 | 5.06 |
| COP | 3.11 | 3.04 | 3.21 | 3.35 | 3.22 | 3.16 |
| Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C | ||||||
| Nominal Capacity (kW) | 6.0 | 8.0 | 10.0 | 12.0 | 14.0 | 16.0 |
| Nominal Power Input (kW) | 1.18 | 1.58 | 1.94 | 2.32 | 2.78 | 3.37 |
| EER | 5.08 | 5.06 | 5.15 | 5.18 | 5.03 | 4.75 |
| Operating Ranges & Capacity Ratings | ||||||
| Heating Capacity Range (kW) | 3.4~8.5 | 4.1~11.0 | 4.2~12.9 | 6.3~17.0 | 6.6~19.3 | 7.8~22.0 |
| Heating Power Input Range (kW) | 0.66~1.92 | 0.78~2.56 | 0.82~2.91 | 1.23~4.12 | 1.31~4.79 | 1.55~5.47 |
| COP Range | 4.43~5.26 | 4.30~5.26 | 4.43~5.12 | 4.13~5.12 | 4.03~5.04 | 4.02~5.03 |
| DHW Condition - Ambient Temp.(DB/WB): 20/15°C, Water Temp.(In/Out): 15/55°C | ||||||
| Heating Capacity Range (kW) | 4.6~9.5 | 5.8~12.0 | 6.0~13.3 | 7.7~18.0 | 8.0~19.5 | 9.3~23.0 |
| Heating Power Input Range (kW) | 0.88~2.07 | 1.13~2.79 | 1.15~2.78 | 1.88~3.98 | 1.56~4.53 | 1.82~5.35 |
| COP Range | 4.59~5.23 | 4.30~5.13 | 4.78~5.21 | 4.38~5.32 | 4.30~5.13 | 4.30~5.11 |
| Heated Water Output (L/H) | 205 | 258 | 285 | 365 | 419 | 494 |
| Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 12/7°C | ||||||
| Cooling Capacity Range (kW) | 2.2~6.0 | 3.3~8.0 | 3.4~10.5 | 5.0~13.2 | 5.6~15.2 | 6.4~16.5 |
| Cooling Power Input Range (kW) | 0.62~1.93 | 0.88~2.59 | 0.9~3.25 | 1.49~4.52 | 1.42~4.81 | 1.93~5.79 |
| EER Range | 3.11~3.55 | 3.09~3.75 | 3.23~3.78 | 2.92~3.35 | 3.16~3.94 | 2.85~3.31 |
| Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C (Range) | ||||||
| Cooling Capacity Range (kW) | 3.3~8.0 | 4.5~10.8 | 5.1~13.0 | 7.9~17.0 | 8.2~18.5 | 9.5~20.5 |
| Cooling Power Input Range (kW) | 0.59~1.88 | 0.80~2.51 | 0.84~2.78 | 1.40~3.72 | 1.42~4.20 | 1.76~5.06 |
| EER Range | 4.26~5.60 | 4.30~5.63 | 4.68~6.07 | 4.56~5.62 | 4.40~5.77 | 4.05~5.40 |
| Energy Efficiency Ratings (ErP) | ||||||
| ErP Level (55°C) | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
| ErP Level (35°C) | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
| Electrical & Hydraulic Specifications | ||||||
| Power Supply | 220-240V~, 50/60Hz | 220-240V~, 50/60Hz | 220-240V~, 50/60Hz | 220-240V~, 50/60Hz | 220-240V~, 50/60Hz | 220-240V~, 50/60Hz |
| Max. Power Input (kW) | 3.2+3.0 | 4.2+3.0 | 5.0+3.0 | 5.8+3.0 | 6.7+3.0 | 8.3+3.0 |
| Max. Current (A) | 14.6+13.8 | 19.2+13.8 | 21.7+13.8 | 25.2+13.8 | 30.7+13.8 | 38.0+13.8 |
| Water Flow (m³/h) | 1.46 | 1.89 | 2.22 | 2.92 | 3.52 | 3.78 |
| Water Pressure Drop (max) kPa | 30 | 35 | 40 | 43 | 58 | 60 |
| Diameter of Pipe (mm) | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 |
| Physical & Operating Specifications | ||||||
| Net Weight (kg) | 128 | 165 | 170 | 178 | 182 | 190 |
| Body Size (W*D*H) (mm) | 1200×465×791 | 1328×485×1065 | 1328×485×1065 | 1328×485×1065 | 1328×485×1065 | 1328×485×1065 |
| IP Grade (Level of Protection) | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
| Refrigerant | R290 | R290 | R290 | R290 | R290 | R290 |
| Expansion Tank (L) | 6L | 6L | 6L | 6L | 6L | 6L |
| Electric Heater | 3kW | 3kW | 3kW | 3kW | 3kW | 3kW |
| Operating Ambient Temp. (°C) | -25~43°C | -25~43°C | -25~43°C | -25~43°C | -25~43°C | -25~43°C |
| Operating Water Temp. (°C) | 25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
25~70°C (DHW) 25~75°C (Heating) 5~25°C (Cooling) |
| Note: The data above is for reference only, please refer to the nameplate on the unit for more specific data. | ||||||