Quality Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology factory
Quality Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology factory

Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology

Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
PRODUCT MODEL
PW08-DKXLRE1-H8
Trading Properties
Payment Method
L/C,D/A,D/P,T/T
Product Summary

R290 Full DC Inverter Monobloc Air Source Heat Pump – H8 Helios Pro Series The H8 Helios Pro Series is an advanced R290 air source heat pump designed to provide efficient heating, cooling, and domestic hot water from a single compact monobloc system. Powered by Full DC Inverter technology, the H8 ...

Product Details
Highlight:

Residential Air Source Heat Pumps IPX4

,

Cold Climate Residential Air Source Heat Pumps

,

Full DC Inverter Air Source Heat Pump

Expansion Tank: 6L
Refrigerant: R290
IP Grade: IPX4
Color: Black
Noise: ≤35dB
Heating Capacity: 6kw-16kw
Type: Air Source Heat Pump
Series: H8 Helios Pro Series
Product Description
R290 Full DC Inverter Monobloc Air Source Heat Pump – H8 Helios Pro Series

The H8 Helios Pro Series is an advanced R290 air source heat pump designed to provide efficient heating, cooling, and domestic hot water from a single compact monobloc system.

Powered by Full DC Inverter technology, the H8 automatically adjusts its operating capacity according to actual heating demand. Combined with natural R290 refrigerant, high-temperature water output, and intelligent control, it provides an efficient and flexible solution for modern residential and commercial heating systems.

With operation down to -25°C and water outlet temperatures up to 75°C, the H8 is engineered for demanding climates and a wide range of heating applications.

Main Features
Full DC Inverter for Efficient Operation

The variable-speed compressor and fan continuously adjust the system output according to the required heating or cooling load.

This helps reduce unnecessary energy consumption while maintaining stable water temperatures and comfortable indoor conditions.

R290 Natural Refrigerant

The H8 uses R290 refrigerant with GWP=3, supporting the transition toward more environmentally friendly heating technologies.

A two-stage refrigerant leakage protection system provides additional safety during operation.

Up to 75°C High-Temperature Water

The H8 can produce outlet water temperatures of up to 75°C, expanding its compatibility with different heating applications.

Reliable Performance in Cold Climates

With a working temperature down to -25°C, the H8 is designed for cold-weather heating applications.

Its AI intelligent defrost system automatically manages defrost cycles to help maintain stable heating performance and minimize unnecessary interruptions.

A+++ Energy Efficiency

The H8 achieves ERP A+++ efficiency at both 35°C and 55°C, making it suitable for both low-temperature and higher-temperature heating systems.

Quiet Heating for Residential Applications

Advanced fan and compressor noise reduction technology keeps operating sound as low as 35 dB(A) at 1 meter.

This makes the system suitable for homes, villas, and other environments where low operating noise is important.

Intelligent Heating Management

The H8 combines local controls with connected smart management functions.

The 7-inch touchscreen controller provides an intuitive interface for daily operation and system configuration.

The temperature curve function helps the system adapt its operation to changing heating requirements and outdoor conditions.

Scalable Cascade Heating

For projects requiring higher heating capacity, up to 8 H8 units can operate in cascade.

This allows the system to be expanded according to project requirements without relying on a single oversized unit.

Suitable for:

  1. Large residential properties
  2. Villas
  3. Apartment buildings
  4. Small commercial buildings
  5. Heating renovation projects
  6. Multi-zone heating systems
Smart Grid Compatible

The H8 Helios Pro Series supports §14a EnWG-compliant operation, making it suitable for applicable German smart-grid applications.

Its smart control architecture allows the heat pump to work with modern energy management strategies and helps optimize electricity usage.

Designed for Modern Heating Systems

The H8 combines several functions in one system:

Heating + Cooling + DHW

This makes it a flexible alternative to traditional heating equipment while reducing the need for multiple independent systems.

Its monobloc configuration also simplifies system integration by keeping the refrigeration circuit within the outdoor unit.

Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology

Cold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter TechnologyCold Climate R290 Residential Air Source Heat Pumps IPX4 Full DC Inverter Technology

Model Series
Parameter / Feature PW06 PW08 PW10 PW12 PW14 PW16
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 30/35°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.19 1.64 2.03 2.39 2.92 3.26
COP 5.04 4.89 4.92 5.03 4.80 4.90
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 47/55°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.93 2.63 3.12 3.58 4.35 5.06
COP 3.11 3.04 3.21 3.35 3.22 3.16
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C
Nominal Capacity (kW) 6.0 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.18 1.58 1.94 2.32 2.78 3.37
EER 5.08 5.06 5.15 5.18 5.03 4.75
Operating Ranges & Capacity Ratings
Heating Capacity Range (kW) 3.4~8.5 4.1~11.0 4.2~12.9 6.3~17.0 6.6~19.3 7.8~22.0
Heating Power Input Range (kW) 0.66~1.92 0.78~2.56 0.82~2.91 1.23~4.12 1.31~4.79 1.55~5.47
COP Range 4.43~5.26 4.30~5.26 4.43~5.12 4.13~5.12 4.03~5.04 4.02~5.03
DHW Condition - Ambient Temp.(DB/WB): 20/15°C, Water Temp.(In/Out): 15/55°C
Heating Capacity Range (kW) 4.6~9.5 5.8~12.0 6.0~13.3 7.7~18.0 8.0~19.5 9.3~23.0
Heating Power Input Range (kW) 0.88~2.07 1.13~2.79 1.15~2.78 1.88~3.98 1.56~4.53 1.82~5.35
COP Range 4.59~5.23 4.30~5.13 4.78~5.21 4.38~5.32 4.30~5.13 4.30~5.11
Heated Water Output (L/H) 205 258 285 365 419 494
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 12/7°C
Cooling Capacity Range (kW) 2.2~6.0 3.3~8.0 3.4~10.5 5.0~13.2 5.6~15.2 6.4~16.5
Cooling Power Input Range (kW) 0.62~1.93 0.88~2.59 0.9~3.25 1.49~4.52 1.42~4.81 1.93~5.79
EER Range 3.11~3.55 3.09~3.75 3.23~3.78 2.92~3.35 3.16~3.94 2.85~3.31
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C (Range)
Cooling Capacity Range (kW) 3.3~8.0 4.5~10.8 5.1~13.0 7.9~17.0 8.2~18.5 9.5~20.5
Cooling Power Input Range (kW) 0.59~1.88 0.80~2.51 0.84~2.78 1.40~3.72 1.42~4.20 1.76~5.06
EER Range 4.26~5.60 4.30~5.63 4.68~6.07 4.56~5.62 4.40~5.77 4.05~5.40
Energy Efficiency Ratings (ErP)
ErP Level (55°C) A+++ A+++ A+++ A+++ A+++ A+++
ErP Level (35°C) A+++ A+++ A+++ A+++ A+++ A+++
Electrical & Hydraulic Specifications
Power Supply 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz 220-240V~, 50/60Hz
Max. Power Input (kW) 3.2+3.0 4.2+3.0 5.0+3.0 5.8+3.0 6.7+3.0 8.3+3.0
Max. Current (A) 14.6+13.8 19.2+13.8 21.7+13.8 25.2+13.8 30.7+13.8 38.0+13.8
Water Flow (m³/h) 1.46 1.89 2.22 2.92 3.52 3.78
Water Pressure Drop (max) kPa 30 35 40 43 58 60
Diameter of Pipe (mm) DN25 DN25 DN25 DN25 DN32 DN32
Physical & Operating Specifications
Net Weight (kg) 128 165 170 178 182 190
Body Size (W*D*H) (mm) 1200×465×791 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065
IP Grade (Level of Protection) IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Refrigerant R290 R290 R290 R290 R290 R290
Expansion Tank (L) 6L 6L 6L 6L 6L 6L
Electric Heater 3kW 3kW 3kW 3kW 3kW 3kW
Operating Ambient Temp. (°C) -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C
Operating Water Temp. (°C) 25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
 
Note: The data above is for reference only, please refer to the nameplate on the unit for more specific data.