DC Inverter R32 Air Source Heat Pump For Residential Swimming Pool
R32 Inverter Swimming Pool Heat Pump for 60–130m³ Pools The R32 Inverter Swimming Pool Heat Pump is developed for medium and large residential swimming pools, with models suitable for pool volumes from 60 to 130m³. Using inverter-driven operation and an R32 refrigerant system, it provides efficient ...
DC Inverter Air Source Heat Pump
,Residential Swimming Pool Air Source Heat Pump
,R32 Residential Air Source Heat Pump
R32 Inverter Swimming Pool Heat Pump for 60–130m³ Pools
The R32 Inverter Swimming Pool Heat Pump is developed for medium and large residential swimming pools, with models suitable for pool volumes from 60 to 130m³.
Using inverter-driven operation and an R32 refrigerant system, it provides efficient pool water heating and cooling while adapting its output to changing operating conditions.
Built for Larger Residential Pools
The series includes multiple models covering different pool sizes:
- 60–120m³
- 70–130m³
- 60–110m³
- 70–130m³
This makes it easier to match the heat pump with the actual pool volume and heating requirements of each project.
High-Efficiency Inverter Technology
The variable-speed compressor continuously adjusts its capacity according to the required heating load.
At 27°C air / 26°C water / 80% humidity, the models achieve a COP of up to 15.0, with a COP of 11.0 at 50% capacity.
Under cooler conditions of 15°C air / 26°C water / 70% humidity, the tested COP range is 4.8–7.0.
This variable-capacity design helps deliver stable performance without continuously running the compressor at full output.
Pool Heating & Cooling
The system provides more than seasonal heating. It also supports pool water cooling, making it suitable for year-round temperature management.
Water temperature range:
- Heating: 9–40°C
- Cooling: 9–35°C
The heat pump can therefore be used to maintain a more comfortable water temperature across different seasons.
Reliable Operation from -7°C to 43°C
With an operating ambient temperature range of -7°C to 43°C, the series can be used in a wide variety of outdoor climates.
The inverter compressor automatically modulates its operating capacity as conditions change, supporting consistent pool temperature control.
Titanium Heat Exchanger
A spiral titanium tube inside a PVC shell is used for the heat exchange system.
The titanium heat exchanger is well suited to swimming pool applications, providing reliable heat transfer and strong resistance to the pool water environment.
Practical Outdoor Design
The heat pump uses a black ABS plastic casing, combining durability with a clean appearance for outdoor pool installations.
Sound pressure is rated at approximately 44–57 dB(A) at 1m, depending on the model. At 50% capacity, sound pressure is approximately 45–49 dB(A).
| Model / Specifications | PW070-KZXYC-H | PW080-KZXYC-H | PW060-KZXYC-H | PW080-KZXYC-H | |
|---|---|---|---|---|---|
| Advised pool volume (m³) | ① | 60~120 | 70~130 | 60~110 | 70~130 |
| Operating air temperature (°C) | -7~43°C | ||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | |||||
| Heating capacity (kW) | 28.0~5.6 | 32.5~6.5 | 24.00~4.80 | 32.5~6.5 | |
| Heating capacity (Btu) | 95500~19100 | 110900~22100 | 81600~16320 | 110900~22100 | |
| Consumed power (kW) | 4.75~0.37 | 5.42~0.43 | 4.00~0.32 | 5.42~0.43 | |
| COP | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | 6.0~15.0 | |
| COP at 50% capacity | 11 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | |||||
| Heating capacity (kW) | 21.8~4.36 | 25.4~5.07 | 18.7~3.42 | 25.4~5.07 | |
| Heating capacity (Btu) | 74380~14880 | 86665~17300 | 63580~11630 | 86665~17300 | |
| Consumed power (kW) | 4.54~0.62 | 5.29~0.72 | 3.89~0.49 | 5.29~0.72 | |
| COP | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | |||||
| Cooling capacity (kW) | 13.8 | 15.6 | 11.8 | 15.6 | |
| General Specifications | |||||
| Sound pressure at 1m | dB(A) | 45~56 | 45~57 | 44~54 | 45~57 |
| Sound pressure of 50% capacity at 1m | dB(A) | 48 | 49 | 45 | 49 |
| Sound pressure at 10m | dB(A) | 26~34 | 26~35 | 25~32 | 26~35 |
| Heat exchanger | Spiral titanium tube in PVC shell | ||||
| Casing | ABS plastic casing black color | ||||
| Refrigerant | R32 | ||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | 220V~230V/1 Ph/50Hz~60Hz | 380V/3 Ph/50Hz/60Hz | 380V/3 Ph/50Hz/60Hz | |
| Water connection (mm) | Φ50 | ||||
| Rated input current at air 15°C (A) | 20.8~2.8 | 24.2~3.3 | 6.9~0.9 | 9.4~1.3 | |
| Advised water flux (m³/h) | 10~14 | 12~16 | 9~12 | 12~16 | |
| Water pressure drop (max) | kPa | 20 | 25 | 15 | 25 |
| Net weight / Gross weight (kg) | 90/105 | 93/108 | 80/94 | 93/108 | |
| Product size (mm) | 1156X433X905 | 1156X433X905 | 1125X416X765 | 1156X433X905 | |
| Operating water temperature (°C) | Heating | 9~40°C | |||
| Operating water temperature (°C) | Cooling | 9~35°C | |||
| ① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover. Note: The data above is for reference only,please refer to the nameplate on the unit if for more specific data. |
|||||