Energy Saving Quiet Pool Heat Pump R32 DC Inverter Silent Pool Heat Pump
Quiet R32 DC Inverter Pool Heat Pump with 40dB operation and COP up to 15.0. ABS housing, app control, solar integration, and titanium heat exchanger ensure durable, efficient heating for residential pools.
Energy Saving Quiet Pool Heat Pump
,Quiet Pool Heat Pump R32
,DC Inverter Silent Pool Heat Pump
The Quiet R32 DC Inverter Pool Heat Pump is built to deliver low-noise, high-efficiency pool heating for private residences. Combining eco-friendly R32 refrigerant with full DC inverter technology, the unit continuously modulates compressor and fan speeds based on real-time thermal load—delivering targeted heating without the power spikes of fixed-speed systems.
Unlike traditional On/Off pool heaters, our variable-speed DC inverter system dynamically adjusts output to match current pool usage and ambient conditions.
- Targeted Output: Automatically ramps down once set temperature is reached, maintaining water temp with minimal power draw.
- Extended Equipment Life: Reduces mechanical wear by eliminating constant full-load start-stop cycles.
- Optimized COP: Maximizes heating efficiency during partial-load operation across spring, summer, and autumn seasons.
- Low-Inrush Current: Smooth soft-start prevents voltage drops on residential electric grids.
Because residential pool equipment is frequently installed near outdoor patio and seating areas, sound control is engineered directly into the refrigeration circuit and cabinet design:
- Brushless DC Fan Motors: Variable fan speeds reduce airflow resistance and blade turbulence.
- Sound-Dampened Cabinet: Acoustic insulation around the compressor attenuates low-frequency operational noise.
- Silent Mode: Programmed ultra-quiet operating profile for night-time temperature maintenance.
The unit transfers thermal energy from ambient air into pool water via a high-grade titanium heat exchanger:
- Corrosion Resistance: Fully compatible with salt-water chlorination systems, chlorine, and pool water treatment chemicals.
- High Heat Transfer Coefficient: Twisted-tube internal geometry maximizes fluid contact and thermal efficiency.
- Grid Electric Offsetting: Replaces direct electric heating elements, dropping operating costs by up to 60–75%.
Designed with a low-profile, weather-resistant outer casing, the unit integrates into residential landscaping and mechanical pads without visual disruption.
- Target Applications:
- Villa & Luxury Residence Swimming Pools
- Private In-ground & Above-ground Pools
- Retrofit & Replacement of Legacy Electric Heaters
- New Residential Pool Construction Projects
The control system includes dedicated dry-contacts and smart-grid interface options for direct integration with residential Photovoltaic (PV) solar installations:
- Solar Prioritization: Run heating cycles during peak daytime solar generation to maximize self-consumption.
- Grid Independence: Lower monthly operational overhead by pairing thermal heat storage with rooftop PV arrays.

| Model / Specifications | PW010-KZXYC-H | PW015-KZXYC-H | PW020-KZXYC-H | PW030-KZXYC-H | PW040-KZXYC-H | PW050-KZXYC-H | PW060-KZXYC-H | |
|---|---|---|---|---|---|---|---|---|
| Advised pool volume | m³ ① | 15~30 | 20~40 | 25~50 | 30~60 | 40~75 | 55~100 | 55~100 |
| Operating air temperature | °C | -7~43°C | ||||||
| Performance Condition: Air 27°C, Water 26°C, Humidity 80% | ||||||||
| Heating capacity | kW | 7.50~1.92 | 9.50~2.10 | 11.00~2.50 | 14.00~3.15 | 17.00~3.75 | 20.00~4.00 | 24.00~4.80 |
| Heating capacity | Btu | 25500~6528 | 32300~7140 | 37400~8500 | 47600~10710 | 57800~13090 | 68000~13600 | 81600~16320 |
| Consumed power | kW | 1.15~0.13 | 1.46~0.14 | 1.83~0.17 | 2.15~0.21 | 2.62~0.25 | 3.33~0.27 | 4.00~0.32 |
| COP | 6.5~14.8 | 6.5~15.0 | 6.0~14.7 | 6.5~15.0 | 6.5~15.0 | 6.0~14.8 | 6.0~15.0 | |
| COP at 50% capacity | 10.5 | 11 | 11 | 10.5 | 11 | 11 | 11 | |
| Performance Condition: Air 15°C, Water 26°C, Humidity 70% | ||||||||
| Heating capacity | kW | 5.80~1.42 | 7.2~1.50 | 8.5~1.65 | 10.7~2.40 | 13.0~2.65 | 15.6~2.85 | 18.7~3.42 |
| Heating capacity | Btu | 19720~4828 | 24480~5100 | 28900~5610 | 36380~8160 | 44200~9010 | 53040~9690 | 63580~11630 |
| Consumed power | kW | 1.15~0.20 | 1.43~0.21 | 1.77~0.23 | 2.12~0.34 | 2.58~0.36 | 3.25~0.40 | 3.89~0.49 |
| COP | 5.0~7.1 | 5.0~7.2 | 4.8~7.2 | 5.0~7.1 | 5.0~7.4 | 4.8~7.0 | 4.8~7.0 | |
| COP at 50% capacity | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | 6.5 | |
| Performance Condition: Air 35°C, Water 28°C, Humidity 80% | ||||||||
| Cooling capacity | kW | 4 | 5.2 | 6 | 7.2 | 8.6 | 10.1 | 11.8 |
| General Specifications | ||||||||
| Sound pressure at 1m | dB(A) | 38~48 | 38~48 | 40~50 | 42~51 | 43~52 | 43~53 | 44~54 |
| Sound pressure of 50% capacity at 1m | dB(A) | 40 | 40 | 41 | 43 | 44 | 44 | 45 |
| Sound pressure at 10m | dB(A) | 18~25 | 18~25 | 19~26 | 22~27 | 23~30 | 24~31 | 25~32 |
| Heat exchanger | Spiral titanium tube in PVC shell | |||||||
| Casing | ABS plastic casing black color | |||||||
| Refrigerant | R32 | |||||||
| Power supply | 220V~230V/1 Ph/50Hz~60Hz | |||||||
| Water connection | mm | Φ50 | ||||||
| Rated input current at air 15°C | A | 5.1~0.9 | 6.3~0.9 | 7.8~1.0 | 9.3~1.5 | 11.3~1.6 | 14.3~1.8 | 17.8~2.3 |
| Advised water flux | m³/h | 2~4 | 2~4 | 3~5 | 4~6 | 6~9 | 8~10 | 9~12 |
| Water pressure drop (max) | kPa | 5 | 5 | 8 | 10 | 12 | 15 | 15 |
| Net weight / Gross weight | kg | 56/68 | 56/68 | 58/70 | 64/76 | 72/86 | 72/86 | 80/94 |
| Product size | mm | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1000X396X640 | 1125X416X765 | 1125X416X765 | 1125X416X765 |
| Operating water temperature | Heating °C | 9~40°C | ||||||
| Operating water temperature | Cooling °C | 9~35°C | ||||||
① The advised pool volumes are valid under ideal conditions: Air 27°C, Water 26°C, Humidity 80%, Pool covered with an isothermal cover.
Note: The data above is for reference only, please refer to the nameplate on the unit if for more specific data.