Quality H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC factory
Quality H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC factory

H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC

H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC
Basic Properties
Country Of Origin
China
Brand Name
ZOVIV
PRODUCT MODEL
PW08-DKXLRE3-H8
Trading Properties
Payment Method
L/C,D/A,D/P,T/T
Product Summary

H8 Helios Pro R290 Full DC Inverter Monoblock Air Source Heat Pump delivers A+++ efficiency for heating, cooling, and hot water with smart control and reliable performance down to -25°C.

Product Details
Highlight:

Residential Air Source Heat Pumps HVAC

,

Monoblock Residential Air Source Heat Pumps

,

R290 Monoblock Air Source Heat Pump

Refrigerant: R290
Application: Outdoor, Hotel, Commercial, Household
App-Controlled: Yes
Warranty: 2 Years
Type: Air Source Heat Pump
Net Weight: 165kg
Product Description
H8 Helios Pro Series Full DC Inverter Monoblock Air Source Heat Pump

The H8 Helios Pro Series Full DC Inverter Monoblock Air Source Heat Pump is an advanced R290 air to water heat pump designed for residential heating, cooling, and domestic hot water. Combining full DC inverter technology with eco-friendly refrigerant, it delivers high efficiency, stable performance, and smart energy management even in extreme cold climates down to -25°C.

High Efficiency & Reliable Performance

With A+++ energy efficiency at 35°C and 55°C water temperatures and a heating COP above 4.5, the H8 Helios Pro provides excellent energy savings and year-round comfort. It supports outlet water temperatures up to 75°C, making it suitable for underfloor heating, radiators, and various home heating systems.

Smart & Quiet Operation

Equipped with AI intelligent defrost technology, a 7-inch touchscreen controller, WiFi remote control, and IoT cloud management, the system ensures easy operation and intelligent energy monitoring. The advanced five-stage noise reduction design achieves operation as low as 35 dB(A) for a quiet home environment.

Safe & Future-Ready Heat Pump Solution

Designed for European markets, the H8 Helios Pro supports R290 natural refrigerant, PV-ready integration, BMS Modbus communication, and German §14a EnWG grid compliance. It is an ideal high efficiency monoblock heat pump solution for modern residential heating, cooling, and hot water applications.

Key Features:

R290 Eco-Friendly Refrigerant

Full DC Inverter Technology

A+++ Energy Efficiency Rating

Heating, Cooling & Hot Water Solution

Operation Down to -25°C Cold Climate

Ultra-Low Noise 35 dB(A)

Smart IoT Remote Control

PV & BMS Compatible

High Efficiency Air Source Heat Pump Solution

H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC

H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC

H8 Helios Pro R290 Monoblock Residential Air Source Heat Pumps Energy Saving HVAC

Model Series

DKXLRE3-H8
Parameter / Feature PW08 PW10 PW12 PW14 PW16
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 30/35°C
Nominal Capacity (kW) 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.64 2.03 2.39 2.92 3.26
COP 4.89 4.92 5.03 4.80 4.90
Heating Condition - Ambient Temp.(DB/WB): 7/6°C, Water Temp.(In/Out): 47/55°C
Nominal Capacity (kW) 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 2.63 3.12 3.58 4.35 5.06
COP 3.04 3.21 3.35 3.22 3.16
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C
Nominal Capacity (kW) 8.0 10.0 12.0 14.0 16.0
Nominal Power Input (kW) 1.58 1.94 2.32 2.78 3.37
EER 5.06 5.15 5.18 5.03 4.75
Operating Ranges & Capacity Ratings
Heating Capacity Range (kW) 4.1~11.0 4.2~12.9 6.3~17.0 6.6~19.3 7.8~22.0
Heating Power Input Range (kW) 0.78~2.56 0.82~2.91 1.23~4.12 1.31~4.79 1.55~5.47
COP Range 4.30~5.26 4.43~5.12 4.13~5.12 4.03~5.04 4.02~5.03
DHW Condition - Ambient Temp.(DB/WB): 20/15°C, Water Temp.(In/Out): 15/55°C
Heating Capacity Range (kW) 5.8~12.0 6.0~13.3 7.7~18.0 8.0~19.5 9.3~23.0
Heating Power Input Range (kW) 1.13~2.79 1.15~2.78 1.88~4.07 1.56~4.53 1.82~5.35
COP Range 4.30~5.13 4.78~5.21 4.38~5.32 4.30~5.13 4.30~5.11
Heated Water Output (L/H) 258 285 365 419 494
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 12/7°C
Cooling Capacity Range (kW) 3.3~8.0 3.4~10.5 5.0~13.2 5.6~15.2 6.4~16.5
Cooling Power Input Range (kW) 0.88~2.59 0.9~3.25 1.49~4.52 1.42~4.81 1.93~5.79
EER Range 3.09~3.75 3.23~3.78 2.92~3.35 3.16~3.94 2.85~3.31
Cooling Condition - Ambient Temp.(DB/WB): 35/24°C, Water Temp.(In/Out): 23/18°C (Range)
Cooling Capacity Range (kW) 4.5~10.8 5.1~13.0 7.9~17.0 8.2~18.5 9.5~20.5
Cooling Power Input Range (kW) 0.80~2.51 0.84~2.78 1.40~3.72 1.42~4.20 1.76~5.06
EER Range 4.30~5.63 4.68~6.07 4.56~5.62 4.40~5.77 4.05~5.40
Energy Efficiency Ratings (ErP)
ErP Level (55°C) A+++ A+++ A+++ A+++ A+++
ErP Level (35°C) A+++ A+++ A+++ A+++ A+++
Electrical & Hydraulic Specifications
Power Supply 380-415V, 3N~, 50/60Hz 380-415V, 3N~, 50/60Hz 380-415V, 3N~, 50/60Hz 380-415V, 3N~, 50/60Hz 380-415V, 3N~, 50/60Hz
Max. Power Input (kW) 4.2+3.0 5.0+3.0 5.8+3.0 6.7+3.0 8.3+3.0
Max. Current (A) 8.0+13.8 9.5+13.8 11+13.8 12.7+13.8 15.8+13.8
Water Flow (m³/h) 1.89 2.24 2.92 3.52 3.78
Water Pressure Drop (max) kPa 35 40 43 58 60
Diameter of Pipe (mm) DN25 DN25 DN25 DN32 DN32
Physical & Operating Specifications
Net Weight (kg) 165 170 178 182 190
Body Size (W*D*H) (mm) 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065 1328×485×1065
IP Grade (Level of Protection) IPX4 IPX4 IPX4 IPX4 IPX4
Refrigerant R290 R290 R290 R290 R290
Expansion Tank (L) 6L 6L 6L 6L 6L
Electric Heater 3kW 3kW 3kW 3kW 3kW
Operating Ambient Temp. (°C) -25~43°C -25~43°C -25~43°C -25~43°C -25~43°C
Operating Water Temp. (°C) 25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
25~70°C (DHW)
25~75°C (Heating)
5~25°C (Cooling)
Note: The data above is for reference only, please refer to the nameplate on the unit for more specific data.